The set duration of the step is timed from the rising edge of the synchronising signal at the
TRIG/SWEEP OUT socket. The minimum step duration of 2ms can be used for frequency
only changes but the time needed to implement waveshape/amplitude/offset changes
determines a practical minimum which is greater than this. Recommended times are
>10ms for frequency plus waveshape changes and >50ms for amplitude and offset
changes. If a shorter duration than that recommended above is set the results will be
unpredictable and it is likely that HOP cannot be turned off in the usual way. To recover
from this situation hold the ESCAPE key down for ~1s until HOP mode is exited.

4.8.5. Saving HOP Settings

The current HOP setting is saved in non-volatile memory at power-down. It is not part of
the data saved by the STORE function (see Storing and Recalling Set-ups section) and
therefore only one complete HOP sequence can be stored. The HOP setting is not lost
when the system defaults are reloaded.
4.9.

System Operations

4.9.1. Storing and Recalling Set-ups

Complete waveform set-ups can be stored to or recalled from non-volatile RAM using the
STORE and RECALL menus.
To store a set-up, press the STORE key in the Utilities section of the keyboard; the display
shows the following message:
Nine stores, numbered 1 to 9 inclusive, are available. Select the store number using the
rotary control or direct keyboard entry and press CONFIRM to execute the store function.
To recall a set-up, press the RECALL key; the display shows the following:
In addition to the user-accessible stores numbered 1 to 9, store 0 contains the factory
defaults which can be reloaded in the same way.
Note that loading the defaults does not change the HOP set-up or any of the other set-ups
stored in memories 1 to 9.

4.9.2. System Settings

This section deals with a number of system settings which can be changed to suit the user.
These are the cursor style, the power-up setting and rotary control status. In addition, the
function of the rear panel CLOCK IN/OUT socket is set from this menu.
34 - II
SAVE TO STORE NO: 1
CONFIRM TO EXECUTE
RECALL STORE NO: 0
0 FOR DEFAULTS
CONFIRM TO EXECUTE
CURSOR CHAR=0 [-]
DIAL=UNLOCKED
POWER UP=DEFAULTS
CLOCK BNC=OUTPUT