Function Selection; Main Generator Parameters; Sweep Parameters - Metrix GX1010 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Note that there are no dependent parameters, coupled parameters, overlapping
commands, expression program data elements or compound command program headers
and that each command is completely executed before the next command is started. All
commands are sequential and the operation complete message is generated immediately
after execution in all cases.
The following nomenclature is used:
<pmt>
<rmt>
<cpd>
<nrf>
<nr1>
<nr2>
[...]
The commands which begin with a
commands. All will function when used on the ARC interface but some are of little use.

5.2.1. Function Selection

SINE
SQUARE
TRIAN
POSPUL
NEGPUL
POSRAMP
NEGRAMP
STAIR
ARB
NOISE
<cpd>

5.2.2. Main Generator Parameters

OUTPUT <cpd>
FREQ <nrf>
PER <nrf>
EMFPP <nrf>
EMFRMS <nrf>
PDPP <nrf>
PDRMS <nrf>
DBM (nrf>
ZOUT <nrf>
DCOFFS <nrf>
SYMM <nrf>
PHASE <nrf>

5.2.3. Sweep Parameters

SWEEP <cpd>
SWPBEGFRQ <nrf>
46 - II
<PROGRAM MESSAGE TERMINATOR>
<RESPONSE MESSAGE TERMINATOR>
<CHARACTER PROGRAM DATA
or OFF.
A number in any format. e.g. 12, 12·00, 1·2 e1 and 120 e-1 are all accepted
as the number 12. Any number, when received, is converted to the required
precision consistent with the use then rounded up to obtain the value of the
command.
A number with no fractional part, i.e. an integer.
A number in fixed point format, e.g. 11·52, 0·78 etc.
Any item(s) enclosed in these brackets are optional parameters. If more
than one item is enclosed then all or none of the items are required.
Set sine function
Set square function
Set triangle function
Set positive pulse function
Set negative pulse function
Set positive ramp function
Set negative ramp function
Set staircase function
Set arbitrary function
Set NOISE <ON> or <OFF>
Set output <ON>, <OFF>, <NORMAL> or <INVERT>
Set main frequency to <nrf> Hz
Set main period to <nrf> seconds
Set output level to <nrf> emf Vpp
Set output level to <nrf> emf Vrms
Set output level to <nrf> pd Vpp
Set output level to <nrf> pd Vrms
Set output level to <nrf> pd dBm
Set output impedance to <nrf>; only 50 or 600 are legal.
Set dc offset to <nrf> Volts
Set symmetry to <nrf> %
Set phase to <nrf> degrees
Set sweep mode to <ON> or <OFF>
Set sweep begin frequency to <nrf> Hz
>, i.e. a short mnemonic or string such as ON
*
are those specified by IEEE Std. 488.2 as Common
GX1010

Publicité

Chapitres

Table des Matières
loading

Table des Matières