European technical assessment E T A - 2 0 / 0 5 4 1
English translation prepared by CSTB
Table C37: Displacements for threaded rods under tension load for seismic
category C2 in concrete
Threaded rod, HAS-U-..., HIT-V-..., AM...8.8
Threaded rod, HAS-U-...,
HIT-V-..., AM...8.8
Table C38: Displacements for threaded rods under shear load for seismic
category C2 in concrete
Threaded rod, HAS-U-..., HIT-V-..., AM...8.8
Installation with Hilti Filling Set
HAS-U 8.8, HIT-V 8.8, AM 8.8
Installation without Hilti Filling Set
Threaded rod, HAS-U-...,
HIT-V-..., AM 8.8
HAS-U 8.8 HDG, HIT-V-F 8.8,
AM HDG 8.8
1)
No performance assessed.
Injection system Hilti HIT-RE 500 V4
Performance
Displacements for seismic category C2 in concrete
M12
[mm]
0,2
N,C2(DLS)
[mm]
0,6
N,C2(ULS)
M12
[mm]
0,2
V,C2(DLS)
[mm]
0,6
V,C2(ULS)
[mm]
1,9
V,C2(DLS)
[mm]
4,4
V,C2(ULS)
[mm]
2,2
V,C2(DLS)
[mm]
4,1
V,C2(ULS)
Page 61 sur 61 | 0 4 / 0 9 / 2 0 2 1
M16
M20
M24
0,5
0,5
0,4
1,2
0,9
0,8
M16
M20
M24
0,5
0,5
0,4
1,2
0,9
0,8
3,2
2,5
3,5
9,2
7,1
10,2
2,3
3,8
3,4
4,3
9,1
8,4
M27
M30
0,4
0,5
1,0
0,9
M27
M30
0,4
0,5
1,0
0,9
3,0
1,9
7,2
6,3
1)
1)
Annex C38