European technical assessment E T A - 2 0 / 0 5 4 1
English translation prepared by CSTB
Specifications of intended use
Anchorages subject to:
Static and quasi static loading.
Seismic performance category C1.
Seismic performance category C2 (HAS-U (8.8, 8.8 HDG, A4, HCR), HIT-V (-8.8, -8.8F, -R, -HCR), AM
(8.8, 8.8 HDG) and standard threaded rod (grade 8.8, A4, HCR)), with hammer drilling and hammer
drilling with Hilti hollow drill bit TE-CD, TE-YD.
Base material:
Compacted reinforced or unreinforced normal weight concrete without fibres according to
EN 206:2013+A1:2016.
Strength classes C20/25 to C50/60 according to EN 206:2013+A1:2016.
Cracked and uncracked concrete.
Temperature in the base material:
at installation
-5 °C to +40 °C for the standard variation of temperature after installation
in-service
Temperature range I:
Temperature range II: -40 °C to +55 °C
Temperature range III: -40 °C to +75 °C
Use conditions (Environmental conditions):
Structures subject to dry internal conditions (all materials).
For all other conditions according EN 1993-1-4:2006+A1:2015-06 corresponding to corrosion resistance
classes Annex A (stainless steel and high corrosion resistant steel).
Design:
Anchorages are designed under the responsibility of an engineer experienced in anchorages and
concrete work.
Verifiable calculation notes and drawings are prepared taking account of the loads to be anchored. The
position of the fastener is indicated on the design drawings (e. g. position of the fastener relative to
reinforcement or to supports, etc.).
The anchorages are designed in accordance with EN 1992-4:2018 and EOTA Technical Report TR 055.
Anchorages under seismic actions shall be positioned outside of critical regions (e.g. plastic hinges) of
the concrete structure. Fastening in stand-off installation or with a grout layer under seismic action are
not covered in this European technical assessment (ETA).
Installation:
Use category:
dry or wet concrete (not in water-filled drill holes): for all drilling techniques.
water-filled drill holes: for hammer drilling only, for uncracked concrete only.
Drilling technique:
hammer drilling,
hammer drilling with Hilti hollow drill bit TE-CD, TE-YD,
diamond coring, for uncracked concrete only,
diamond coring with roughening with Hilti Roughening tool TE-YRT.
Installation direction D3: downward, horizontal and upward (e.g. overhead) installation admissible for all
elements.
Fastener installation carried out by appropriately qualified personnel and under the supervision of the
person responsible for technical matters of the site.
Injection system Hilti HIT-RE 500 V4
Intended use
Specifications
-40 °C to +40 °C
(max. long term temperature +24 °C and max. short term temperature +40 °C)
(max. long term temperature +43 °C and max. short term temperature +55 °C)
(max. long term temperature +55 °C and max. short term temperature +75 °C)
Page 10 sur 61 | 0 4 / 0 9 / 2 0 2 1
Annex B1