Hilti HIT-RE 500 V4 Mode D'emploi page 26

Masquer les pouces Voir aussi pour HIT-RE 500 V4:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

European technical assessment E T A - 2 0 / 0 5 4 1
English translation prepared by CSTB
Table C1:
continued (1)
Threaded rod, HAS-U-..., HIT-V-..., AM...8.8
Combined pullout and concrete cone failure for a working life of 50 years
Characteristic resistance in uncracked concrete C20/25
in hammer drilled holes and hammer drilled holes with Hilti hollow drill bit TE-CD or TE-YD
and diamond cored holes with roughening with Hilti Roughening tool TE-YRT
Temperature range I:
Temperature range II:
Temperature range III:
Characteristic resistance in uncracked concrete C20/25
in diamond cored holes
Temperature range I:
Temperature range II:
Temperature range III:
Characteristic resistance in uncracked concrete C20/25
in hammer drilled holes and installation in water-filled drill holes
Temperature range I:
Temperature range II:
Temperature range III:
Characteristic resistance in cracked concrete C20/25
in hammer drilled holes and hammer drilled holes with Hilti hollow drill bit TE-CD or TE-YD
and diamond cored holes with roughening with Hilti Roughening tool TE-YRT
Temperature range I:
Temperature range II:
Temperature range III:
Influence factors  on bond resistance 
Influence of concrete strength
in hammer drilled holes and hammer drilled holes with Hilti hollow drill bitTE-CD or TE-YD
and diamond cored holes
Temperature range I to III:
in diamond cored holes with roughening with Hilti Roughening tool TE-YRT
Temperature range I to III:
Influence of sustained load
in hammer drilled holes and hammer drilled holes with Hilti hollow drill bit TE-CD or TE-YD
and diamond cored holes with roughening with Hilti Roughening tool TE-YRT
Temperature range I:
Temperature range II:
Temperature range III:
in diamond cored holes
Temperature range I:
Temperature range II:
Temperature range III:
Injection system Hilti HIT-RE 500 V4
Performance
Essential characteristics under tension load in concrete
40°C / 24°C
[N/mm
Rk,ucr
55°C / 43°C
[N/mm
Rk,ucr
75°C / 55°C
[N/mm
Rk,ucr
40°C / 24°C
[N/mm
Rk,ucr
55°C / 43°C
[N/mm
Rk,ucr
75°C / 55°C
[N/mm
Rk,ucr
40°C / 24°C
[N/mm
Rk,ucr
55°C / 43°C
[N/mm
Rk,ucr
75°C / 55°C
[N/mm
Rk,ucr
40°C / 24°C
[N/mm
Rk,cr
55°C / 43°C
[N/mm
Rk,cr
75°C / 55°C
[N/mm
Rk,cr
in cracked and uncracked concrete
Rk
c
c
0
40°C / 24°C
sus
55°C / 43°C
0
sus
0
75°C / 55°C
sus
0
40°C / 24°C
sus
0
55°C / 43°C
sus
0
75°C / 55°C
sus
Page 25 sur 61 | 0 4 / 0 9 / 2 0 2 1
M8
M10
M12
2
]
19
18
18
2
]
16
15
15
2
]
6,0
6,0
6,0
2
]
13
13
13
2
]
12
12
11
2
]
6,0
5,5
5,5
2
]
16
16
15
2
]
13
13
13
2
]
5,0
5,0
5,0
2
]
7,5
9,0
11
2
]
7,0
8,0
9,0
2
]
4,0
3,5
3,5
[-]
)
2
[-]
[-]
[-]
[-]
[-]
[-]
[-]
M16
M20
M24
M27
17
16
15
15
14
13
13
12
5,5
5,0
5,0
4,5
13
12
12
12
11
11
11
11
5,5
5,5
5,5
5,5
15
14
13
12
12
11
11
10
4,5
4,5
4,0
4,0
11
10
9,5
9,0
8,5
8,0
8,0
7,5
3,5
3,0
3,0
3,0
0,1
(f
/20)
ck
1,0
0,88
0,72
0,69
0,89
0,70
0,62
Annex C2
M30
14
12
4,5
12
10
5,0
12
10
4,0
8,5
7,0
3,0

Publicité