SYSTEM ERRORS AND FAULTS
SYSTEM ERRORS
System errors may arise when the chain counter chain counter is turned on.
Checksum error
The following windows are displayed if the counter detects an error in the memorized data:
CONTROL CHECKSUM
FLASH CHECKSUM
TRUE:
SUM:
FLASH memory checksum error
If one of these messages appears do not use the chain counter and contact a service center or QUICK
customer service without delay.
Multi Master error
If the chain counter detects more then one of MASTER chain counters in
the CAN network, the following window is displayed:
Select chain counter»s priority in the CAN network
(see chapter MULTIPLE CHAIN COUNTERS).
SYSTEM FAULTS
System faults that appear on the state line divided into three categories which are shown below: prob-
lems with automatic reset, problems with automatic reset and keys locked and problems with manual
reset.
PROBLEMS WITH AUTOMATIC RESET
These faults are automatically reset as soon as the cause that had generated the problem disappears.
Low voltage
This fault is displayed if the voltage drops below 10.5Vdc for more than
one second. Reset takes place if the voltage is higher than 11.0Vdc for
more than one second. Check the charge level of the batteries that supply
voltage or the electrical system.
The window shown below appears when this problem is present:
Clock battery low
This fault is displayed if the voltage of the clock battery drops below
2.80Vdc. The chain counter checks the battery voltage when turned on and
every half hour. The problem is reset if the voltage is higher than or equal
to 2.80Vdc. The clock battery can be replaced only at an authorized service
center.
The window shown below appears when this problem is present:
28
ERROR
XXXX
YYYY
CONTROL EEPROM
EEPROM CHECKSUM
ERROR
TRUE:
SUM:
EEPROM memory checksum error
MULTI MASTER
LOW VOLTAGE
SPEED
CLOCK BAT LOW
SPEED
XXXX
YYYY
ERROR
SET VALUE:
MASTER
SLAVE
0 M / M
0 M / M
®