4.2 Block assembly
The following drawing shows in an example the components which belong
to a block and the place where the accessories can be used.
7
8
9
5
Technical daTa
5.1 Operating conditions
The following values are indicated on the type label:
• Voltage (Tolerance ± 10 %) / Current type
• Coil power consumption (active power in W - at operating temp.)
• Pressure range
• Body material: Glass fiber reinforced polyamide,
connections: Brass (MS)
• Sealing material: FKM, EPDM, NBR
• Function of the valve: Collectors or distributors can be mixed
on the block
Circuit function 2/2-way valve:
A (NC)
Protection class:
IP65 in accordance with DIN EN 60529 / IEC
60529 with cable plug, e.g. Bürkert Type 2508
6
Important information for functional reliability during continuous
operation: If standstill for a long period at least 1-2 activations
per day are recommended.
Service life:
High switching frequency and high pressures
reduce the service life
5.3 conformity
In accordance with the EC Declaration of conformity, Type 0287 is com-
pliant with the EC Directives.
5.4 standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity.
1
2
3
4
5
6
B (NO)
english
Pos.
Description
1
2 Pull rods
2
Dummy plate or connection
without Quad ring
3
SV module with or without
adapter
1)
or T-module
2)
with
Quad ring
4
Additional connection
5
SV module or T-module with
Quad ring
The adapter allows:
1)
- an injecting device to be connected for taking samples
- a sensor to be installed for measuring certain physical or chemical values of
the medium
2)
T-module: Feed module with G1/2" connection, others on request
english
5.2 application conditions
Ambient temperature:
max. +55 °C
Permitted medium temperature and permitted media depending on
sealing material:
Sealing
Medium
material
temperature
Diesel and heating oil without additives,
FKM
0 ... +70 °C
water with additives
Oil and grease-free liquids, cold and
EPDM
0 ... +70 °C
hot water
NBR
0 ... +70 °C
Water
Operating duration:
Unless otherwise indicated on the type label,
the solenoid system is suitable for continuous
operation.
For models with a high-power coil a maximum of
6 switching operations per minute are possible.
This applies to devices with power rating
80/6 W.
5.5 Type label
Orifice
Sealing material
Circuit
function
Type
0287 A 13,0 NBR
G1/2
P N 0.5 - 10 bar
24 V 50-60 Hz 5W
Verteiler
00017317
W17MG
Id. Number
Manufacturer code
english
Type 0287
Pos.
Description
6
Partition wall with O-ring
7
SV module with or without
adapter
or T-module with
1)
Quad ring
8
Dummy plate or connection
with Quad ring
9
2 mounting brackets
Permitted media
Body material
MS
Connection thread, Operating
pressure
Voltage, Frequency,
Power consumption
Function of the valve
5
7