closure). In case automatic closure is
not enabled, the lamp remains lit only
during movement (E-EX, dip n°16 OFF
- 17 ON);
-Courtesy Light. A light that illuminates
the manoeuvring zone; after an open-
ing command, the light remains on for
a fixed time of 5 minutes and 30 sec-
onds (E-EX, dip n°16 ON - 17 OFF);
- Open gate pilot lamp. It is a light
that indicates the sliding gate's open
position and turns off when the gate
activates the closing end-stop.
Other functions
- Automatic closing. The automatic
closing timer is automatically activated
at the end of the opening cycle. The
preset, adjustable automatic closing
time is automatically interrupted by the
activation of any safety system, and is
deactivated after a STOP command or
in case of power failure;
-Partial opening. Opening of the gate
to allow for foot traffic; activated by
connecting to terminals 2-3P and adju-
sted with the AP-PARZ. trimmer. With
this function, the automatic closing can
vary in the following way:
1) Dip 12 set to ON: after a partial
opening, the time for automatic closing
functions independently of the adjust-
ment of the TCA trimmer and of the po-
sition of Dip 1; it is set at 8 seconds.
2) Dip 12 set to OFF: after a partial
opening, the time for automatic closing
is adjustable only if Dip 1 is set to ON.
- "Operator present". Gate operates
only when the pushbutton is held down
(the radio remote control system is
deactivated);
- Pre-flashing. After an opening or clo-
sing command, the flasher connected
to the W-E flashes for 5 seconds befo-
re beginning the procedure;
-Type of command:
-Open-stop-close-stop by button and
transmitter;
-Open-close by button and transmitter;
-Open only by transmitter.
Adjiustments
- Operating time;
- Automatic closure time;
- Partial opening time.
Caution! Disconnect the unit from
the main power lines before carrying
out any operation inside the unit.
-5-