Electrically connect the compressor per Chapter 13.
Insert the compressor into the cabinet using the pulling system (24), place the connecting strip
in front of the cabinet and adjust the position of the compressor so that the two "V" notches on
the connecting strip (17) align with the compressor legs (Fig. 4). This puts the compressor in
the right position inside the cabinet.
Check to ensure the compressor is fully inserted into the cabinet using the control dimension
(Fig. 16).
Fig. 16: Positioning of the DK50 2V/50/M compressor in the cabinet
Place the connecting strip (17) in its original position in the lower part of the cabinet.
Connect the cabinet pressure gauge to the compressor per Chapter 12.2.
Do not push the compressor all the way to the back of the cabinet as it may
permanently damage the dryer.
Cabinet door installation
Attach the door to the cabinet, connect the display connector (Fig. 17) and secure the cord to
the display in the clamp (1) in the front door (Fig. 18).
Connect the earthing lead to the door and mount the door to the cabinet using 2 screws.
NP-DK50 2V 50, 2x2V 110-AD-1_03-2022
42
INSTALLATION
03/2022