Settings; Appliance Shutdown - Stiebel Eltron SHP-F 220 Premium Utilisation Et Installation

Masquer les pouces Voir aussi pour SHP-F 220 Premium:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

iNSTallaTiON

Settings

12. Settings
Service menu
To unlock the service menu, you need to connect a service plug
or enter a code.
Accessing the service menu with a service plug
1
1 Slot X1
f Plug the service plug into slot X1 on the back of the program-
f
ming unit.
Accessing the service menu by entering a code
Press the "Menu" button for longer than
3 s. The software version number of the
controller PCB appears.
Display
301
To display the software version number
of the programming unit PCB, press the
"Plus" button.
Display
-103
To go to code entry, press the "Minus"
button.
To go from the software version num-
ber of the controller PCB directly to code
entry, press the "Minus" button.
To go to the code digit check, press the
"Rapid heat-up" button. The currently
active digit flashes.
Set the first digit using the "Plus" and
"Minus" buttons.
To set the next digit, press the "Rapid
heat-up" button.
To confirm the code after entering all
digits, press the "Rapid heat-up" but-
ton.
28
| SHP-F 220-300 Premium
Version number
3.1.00
Version number
1.3.00

Service menu

Integral sensor offset

Set the cylinder volume

Compressor lockout due to evaporator fault

Clear high pressure lockout

Clear low pressure lockout

Temperature of evaporator fins

Number of times hot gas temperature sensor was triggered

Number of defrost faults

Number of low pressure triggers

Number of high pressure triggers

Hot gas temperature switching value

Fan lead time

Integral sensor replacement

Set value limit
The parameters in this menu are reserved for qualified contrac-
tors.

13. Appliance shutdown

Material losses
!
If you disconnect the appliance from the power supply, it
is no longer protected against frost or corrosion.
f Only disconnect the appliance from the power sup-
f
ply for longer periods if you are also draining the
DHW cylinder.
The appliance can only be switched off by interrupting the power
supply.
f Pull the mains plug from the socket or disconnect the appli-
f
ance from the mains at the MCB/fuse in the fuse box.
14. Troubleshooting
WARNING Electrocution
Prior to all work on the appliance, isolate it from the
power supply.
Material losses
!
If you disconnect the appliance from the power supply, it
is no longer protected against frost or corrosion.
f Only disconnect the appliance from the power sup-
f
ply for longer periods if you are also draining the
DHW cylinder.
f For work inside the appliance, remove the appliance cover
f
(see chapter "Cleaning and maintenance / Removing the ap-
pliance cover").
f If necessary, remove the upper section of the casing jacket
f
(see chapter "Maintenance and cleaning / Removing the cas-
ing ring").
Note
Refit the casing ring after completing the work. See chap-
ter "Maintenance and cleaning / Fitting the casing ring").
www.stiebel-eltron.com

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Shp-f 300 premiumShp-f 300 x premium

Table des Matières