Settings - Stiebel Eltron SHP-F 220 Premium Utilisation Et Installation

Masquer les pouces Voir aussi pour SHP-F 220 Premium:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPEraTiON

Settings

4.2
Settings
Menu
The default display shows the mixed water volume.
The "Menu" button allows you to call up
all information and adjustment options in
sequence. The relevant symbol appears.

Menu

"Mixed water volume" display

"Actual temperature" display

Set temperature 1

Set temperature 2

Fan speed

"Air intake temperature" display

Enable the "Runtime-dependent rapid heat-up" function

Time input for the "runtime-dependent rapid heat-up" function

Change units

Fault code

E fault code

"Mixed water volume" display
The currently available amount of mixed
water at 40 °C and at 15 °C cold water
temperature is shown.
"-- L" is shown if less than 10 l mixed
water is available.
DHW demand for
Bath
Shower
Washing hands
The mixed water volume that can be achieved depends on the
cylinder size and the set temperature selected.

"Actual temperature" display
In the "Mixed water volume" menu, press
"Menu" once to access the "Actual tem-
perature" menu.
The "Actual temperature" symbol ap-
pears.
The current actual temperature is shown.
The actual temperature indicates the
temperature in the upper section of the
DHW cylinder and largely corresponds to
the outlet temperature.
www.stiebel-eltron.com
Mixed water volume at 40 °C
120 - 150 l
30 - 50 l
2 - 5 l

Set temperature  1
Note
For hygiene reasons, never set the DHW temperature
below 50 °C.
Set temperature 1 is the DHW temperature to which the appliance
regulates if no external signal transmitter is connected and active.
In the "Actual temperature" menu, press
"Menu" once to access the "Set temper-
ature 1" menu.
"Set temperature 1" symbol appears.
You can change the value using the "Plus"
and "Minus" buttons. Setting range: 20
- 65  °C
Note
Another way to adjust set temperature 1 is to press the
"Plus" or "Minus" keys from within the default display
(mixed water volume).
Frost protection
Only frost protection remains active if
you set the set temperature to below
20 °C using the "Minus" key. The display
shows "-- °C".

Set temperature  2
Note
For hygiene reasons, never set the DHW temperature
below 50 °C.
Set temperature 2 is the DHW temperature to which the appliance
regulates if an external signal transmitter is connected and active.
In the "Set temperature 1" menu, press
"Menu" once to access the "Set temper-
ature 2" menu.
The "External signal transmitter" symbol
appears.
You can change the value using the "Plus"
and "Minus" buttons. Setting range: 20
- 65  °C
SHP-F 220-300 Premium |