Stiebel Eltron SHP-F 220 Premium Utilisation Et Installation page 24

Masquer les pouces Voir aussi pour SHP-F 220 Premium:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

iNSTallaTiON
installation
GNYE
PE
BU
N
A
BN
L
N
B
L1 / L2 / L3
A
Power supply provided by power supply utility or energy
management system for switching the load (compressor)
B
Power supply to impressed current anode and PCB
BN
Brown
BU
Blue
GNYE Green/yellow
f Connect the electric cables for the separate impressed cur-
f
rent anode power supply to X0/1 and X0/2.
Material losses
!
The power supply to the impressed current anode must
be ensured at all times.
Material losses
!
With regard to the external switching device, the min-
imum runtime and minimum pause times must be ob-
served (see chapter "Appliance description/Minimum
runtime and minimum pause time").
10.5.3 Connection options: Operation with external signal
transmitter
Material losses
!
See "Permissible voltage range for external signal trans-
mitters" in chapter "Specification/data table".
Note
The appliance has a second, higher set temperature
which is selected at the factory. This is activated when
there is an external switching signal. Set temperature 2 is
higher ranking than the standard set temperature while
there is an external switching signal.
An external signal transmitter for switching a separate set DHW
temperature (set temperature 2) can be connected to terminal
X3/1-2. In the delivered condition, terminal X3/1-2 is not assigned.
If this terminal is connected at the voltage stated in the specifica-
tion (see "Permissible voltage range, external signal transmitter")
(L to X3/1, N to X3/2), the appliance enables set temperature 2.
24
| SHP-F 220-300 Premium
X0
PE
PE
N
N
X3
L
3
L
3
2
2
2
2
1
1
1
1
Following one-off activation (signal present for at least 1 min-
ute), set temperature 2 applies for at least 20 minutes. When
the relevant DHW set temperature has been reached, the com-
pressor switches off and remains off for a minimum idle time of
20 minutes.
The following diagram illustrates the connections by means of a
sample signal sequence from an external signal transmitter.
Example:
- Water temperature = 55  °C
- Set temperature 1 = 50  °C
- Set temperature 2 = 65  °C
A
1
0
0
5
10
15
20
25
30
35
B
1
0
0
5
10
15
20
25
30
35
A External signal
B Compressor
1 20 min. minimum runtime, set temperature 2
2 20 min. minimum compressor idle time
f Remove the appliance cover (see chapter "Cleaning and
f
maintenance / Removing the appliance cover").
1
1 Strain relief
2 Terminal X3
f Prepare the cables in such a way that each cable terminates
f
with a wire ferrule.
f Push the cables through one of the cable entries in the appli-
f
ance casing.
f Route the cables through the strain relief.
f
f Connect the cables to X3.
f
40
45
50
55
60
65
70
75
t [min]
40
45
50
55
60
65
70
75
t [min]
2
www.stiebel-eltron.com
1
2