iNSTallaTiON
installation
Air duct connection
Note
Connect the appliance and the air duct system using a
flexible method, e.g. a flexible ventilation pipe, to reduce
noise and vibrations.
f Connect a flexible 500 cm hose to the air duct.
f
Note
The installation of a thermally insulated air hose is de-
scribed as an example.
1
2
1 Air connector
2 Internal hose
3 External hose
f Pull the internal hose of the air hose slightly out of the exter-
f
nal hose and thermal insulation.
f Invert the internal hose halfway down the connector.
f
20
| SHP-F 220-300 Premium
f Seal the transition from the internal hose to the connector
f
with self-adhesive thermal insulation tape.
f Pull the external hose and the thermal insulation below it
f
over the connector.
f Tuck the thermal insulation into the outer hose in such a way
f
that the thermal insulation is no longer visible.
3
f Seal the transition from the external hose to the connector
f
with self-adhesive thermal insulation tape.
f Secure the external hose with the hose clip to the connector.
f
f The air hose tends to sag because of its flexibility. Secure it
f
at intervals of approx. 1 m.
f Insulate the air duct and all connections in line with insula-
f
tion standards if used for waste heat or outside air to prevent
condensation on these components.
www.stiebel-eltron.com