4.1.2
Format (PARAMETER REQUEST)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS are matched. The data will be
echoed when [PARAMETER CHANGE ECHO] is on. The corresponding
parameter will be changed via PARAMETER CHANGE immediately the data is
received.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0001nnnn 3n
Digital mixer
GROUP ID
00111110 3E
LS9
MODEL ID
00010010 12
DATA Category 0ccccccc cc
Element no High.
DATA
0eeeeeee eh
Element no Low.
0eeeeeee el
Index no High.
0iiiiiii ih
Index no Low.
0iiiiiii il
Channel no High.
0ccccccc ch
Channel no Low.
0ccccccc cl
End of exclusive
EOX
11110111 F7
4.1.3
Data category
DATA CATEGORY
0x01
00000001
4.2 FUNCTION CALL – LIBRARY STORE, RECALL –
4.2.1 Format (PARAMETER CHANGE)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS are matched. The data will be
echoed when [PARAMETER CHANGE ECHO] is on. The corresponding
parameter will be changed immediately the data is received.
Transmission
Data will be transmitted with the [Device Number] (MIDI CH) in [Tx CH]
when [PARAMETER CHANGE Tx] is on.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
LS9
MODEL ID
00010010 12
OTHER DATA
DATA CATEGORY 00000000 00
(ASCII CODE)
FUNCTION NAME 01001100 "L"
(ASCII CODE)
01101001 "i"
(ASCII CODE)
01100010 "b"
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
MODULE NAME
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
Number High
DATA
0nnnnnnn nh
Number Low
0nnnnnnn nl
Channel High
0ccccccc ch
Channel Low
0ccccccc cl
End of exclusive
EOX
11110111 F7
NAME
Current Scene/Setup/Backup/
User Setup Data
4.2.2
Function Name
FUNCTION NAME
Store
"LibStr__"
Recall
"LibRcl__"
Unknown Factor Store
"LibUnStr"
Unknown Factor Recall
"LibUnRcl"
Store Undo (only Scene)
"LibStrUd"
Recall Undo (only Scene)
"LibRclUd"
4.2.3
Module Name
MODULE NAME
Scene
"SCENE___"
Input EQ
"INEQ____"
Output EQ
"OUTEQ___"
Dynamics
"DYNA____"
GEQ
"GEQ_____"
Effect
"EFFECT__"
Function
Number
"LibStr__"
SCENE
1- 300
INPUT EQ LIB
41- 199
OUTPUT EQ LIB
4- 199
Dynamics LIB
42- 199
GEQ LIB
1- 199
EFFECT LIB
58- 199
"LibUnStr"
SCENE
1- 300
INPUT EQ LIB
41- 199
OUTPUT EQ LIB
4- 199
Dynamics LIB
42- 199
GEQ LIB
1- 199
EFFECT LIB
58- 199
"LibRcl__"
SCENE
0- 300
INPUT EQ LIB
1- 199
OUTPUT EQ LIB
1- 199
Dynamics LIB
1- 199
GEQ LIB
0- 199
EFFECT LIB
1- 199
"LibUnRcl"
SCENE
0
INPUT EQ LIB
0
OUTPUT EQ LIB
0
Dynamics LIB
0
GEQ LIB
0
EFFECT LIB
0
"LibStrUd"
SCENE
0
"LibRclUd"
SCENE
0
*1) 0:CH1–63:CH64
64:ST IN 1L–71:ST IN 4R
*2) 256:MIX1–271:MIX16
*3) 512:MATRIX1–519:MATRIX8
*4) 1024:STEREO L–1026:MONO(C)
*5) 512:will be used if the recalling or storing data is only one.
*6) 0:RACK1–7:RACK8 If a GEQ is mounted in RACK 1–8.
*7) 0:RACK5–3:RACK8 If an effect is mounted in RACK 5–8.
*8) 1280:CH 1–1343:CH 64
1344:STIN 1L–1351:STIN 4R
(Dynamics2)
LS9-16/32 Mode d'emploi
Format des données MIDI
channel*1)
tx/rx
*5)
tx/rx
*1)
tx/rx
*2) *3) *4)
tx/rx
*1) *2) *3) *4) *8)
tx/rx
*6)
tx/rx
*7)
tx/rx
0
tx
0
tx
0
tx
0
tx
0
tx
0
tx
*5)
tx/rx
*1)
tx/rx
*2) *3) *4)
tx/rx
*1) *2) *3) *4) *8)
tx/rx
*6)
tx/rx
*7)
tx/rx
*5)
tx
*1)
tx
*2) *3) *4)
tx
*1) *2) *3) *4) *8)
tx
*6)
tx
*7)
tx
0
0
263