Your EuroCave wine cabinet is a tried and tested appliance.
Maintenance to be carried out approximately once a year
Unplug and unload the appliance.
Remove dust from the condenser at the back of the appliance by vacuuming it.
Clean the inside of the compartments with water and a gentle cleaning product.
Rinse thoroughly.
Replace the active charcoal filter, housed in the upper breather hole of your cabinet (see chapter 5).
Remove the charcoal filter manually. It is available from your usual retailer. It must be replaced by an
original manufacturer's part.
Check that the seals are in good condition.
9 - o
Possible incidents
The
pictogram is displayed
The
pictogram is still displayed even
though I have taken the above corrective
action
The
pictogram is displayed
The
pictogram is flashing
The appliance cannot lower the level of
humidity to the desired value
The
pictogram is displayed
The
pictogram is displayed
If your appliance does not seem to be operating correctly, contact your EuroCave retailer.
32
EN
N 83V2-0511.indd 32
veryday maintenance
perating faults
Causes
The temperature has
not returned to within
the ±4 °C threshold
Operating fault
Open door alarm
The relative humidity
level has been < 50 %
for more than 72 hrs
Charcoal filter alarm
Temperature
sensor
fault alarm
"Collection" wine cabinet maintenance:
If there are marks (splashes, finger marks), wipe them with
a damp cloth.
Dust the elements regularly with a dry cloth to keep them
clean.
Use of furniture spray is not necessary or recommended.
If any of the cabinet's panels are damaged, contact your
EuroCave retailer.
Corrective actions
Check that the door is closed. Check the condition of the door seal.
If in the last few hours you loaded your cabinet with a large number of bottles,
wait a while then check again. If the alarm is still displayed, contact your
EuroCave retailer.
Unplug the cabinet and contact your EuroCave retailer.
Ensure that the door is properly shut.
Pour a glass of water into the channel of the tray (see chapter 7, § IV).
In order to know how often to add water, count the number of days
separating the 1st day you added water and the day when the pictogram was
displayed. After a few hours, the pictogram will turn off.
Empty the cabinet, remove the humidity cartridge and clean the tray.
Remove the tube placed at the back of the tray. The humidity will be directly
discharged out of the appliance.
Contact your EuroCave retailer if the problem persists after you have carried
out these corrective actions.
Replace the charcoal filter (see chapter 5).
Contact your EuroCave retailer.