VII- Heating function
The EuroCave INOA conditioner has a heater (650 W) allowing the internal temperature in your cellar to be maintained at an optimal level.
As soon as the temperature drops below the programmed temperature, the heating function is automatically activated.

VIII- Changing the remote control batteries

Remote control power supply: 1 x 3 V (CR 2430 battery) (2 batteries supplied)
Battery life: 2 years approx
The remote control is supplied with 2 batteries. Only one battery is required (pull off the plastic strip to make it
useable).The other battery is a spare.
- When the battery runs out, the
- Take the remote control off the wall.
- On the back of the remote control, push the used battery down using a screwdriver (see diagram opposite).
- Pull the strip from the spare battery, which will then be ready for use.
- Remember to buy a replacement for the spare battery.

IX- Discharging condensate

Your conditioner was designed to allow condensate to be discharged (discharge pipe located under the conditioner's
housing) either inside the cellar, if the humidity level is too low, or outside the cellar.
Simply pass the pipe through the wall to discharge the condensate into the room next to the conditioner housing.
Ensure that the piping is not kinked.
8 - E
Vacuum the 4 air entry and exit grids at least twice a year, ensuring that you first unplug the conditioner. Please
note that a refrigeration engineer must be employed for a more thorough cleaning of your appliance's internal
elements (every two years).
9 - T
Dimensions
Power
in mm
supply
Inoa 25
W385 x D322
230 V
x H1250
/ 50 Hz
Inoa 50
W385 x D322
230 V
x H1250
/ 50 Hz
* in a very well insulated room - ** for an internal temperature of 12° C and an external temperature of 32° C.
*** for an internal temperature of 12° C and an external temperature of 25° C.
Supplied with 3.50 m power lead without plug.
12
OMMISSIONING YOUR CONDITIONER
pictogram flashes on the remote control's display.
VERYDAY MAINTENANCE
ECHNICAL SPECIFICATIONS
Sample
Cooling
Weight
volume m
3
capacity W
Kg
up to
600 W**
43 Kg
25 m
3
*
up to
1200 W**
46 Kg
50 m
3
*
Electrical
Heating
power W
resistance W
550 W**
650 W
800 W**
650 W
Refrigerant
External
temperatures
R134a
-5°C to 35°C
(without CFCs)
R134a
-5°C to 35°C
(without CFCs)
Consumption
per 24h***
3,1 kwh
4,1 kwh