Your EuroCave cigar humidor is an appliance with tried and tested performance.
Maintenance operations to be carried out approximately once a year
Maintenance operations to be carried out every 2 years
Possible incidents
The icon
displays
The icon
is still displayed even
though I have performed the corrective
action above
The icon
displays
The icon
flashes
The apparatus cannot lower the humidity
to the desired level.
The icon
displays
The icon
displays
If your appliance appears to be functioning abnormally, contact your EuroCave dealer.
8 - E
Causes
Corrective action
The temperature
Check the door is closed properly.
has not dropped
Check the condition of the door hinge.
below the limit of
If you have loaded your humidor with a high number of cigars in the past few
±4 °C / 39 °F
hours, wait a short while then check the temperature again.
If the alarm persists, contact your EuroCave dealer.
Operating faults
Disconnect the humidor and contact your EuroCave dealer.
Open door alarm Ensure the door is closed properly.
The relative
Add 10 cl of water into each pozzolana cassette.
humidity rate falls
In order to obtain the time interval for adding water, count the number of days
below 65 % for
between the 1st day when water was added and the day when the pictogram was
more than 72
displayed.
hours
After a few hours the icon will go out.
Empty the humidor, remove the pozzolana cassettes and clean the tank.
Remove the tube positioned on the bottom of the tank. The humidity will be
directly removed from the apparatus.
Adjust the level of humidity to 75 % but do not install the pozzolana cassettes
or replace them with new ones.
Call the EuroCave dealer is the problem persists despite these different actions.
Carbon filter
Replace the carbon filter (see chapter 5).
alarm
Temperature
Contact your EuroCave dealer.
sensor defect
alarm
VERYDAY MAINTENANCE
9 - O
PERATING FAULTS
23
EN