7/ EVERYDAY MAINTENANCE
Your EuroCave wine cabinet is an appliance with tried and tested performance.
Maintenance operations to be carried out every 3 months
•
Remove the 2 screws from the grille with a no. 2 hexagonal spanner (provided int the accessories bag).
•
Remove the grille, take out the filter and place under running water.
•
Leave to dry and refit the assembly.
Maintenance operations to be carried out approximately once a
year
•
Unplug and unload the appliance.
•
Clean the water drain at the bottom of the wine cabinet. Pay attention that nothing is blocking this drain.
•
Clean the inside of the compartments with water and a gentle cleaning product.
•
Rinse thoroughly. Dry it with a soft rag.
•
Replace the active carbon filter housed in the upper ventilation hole in your cabinet (see chapter 6, § VI).
Manually remove the carbon filter. It is available from your usual dealer. It must be replaced using a
manufacturer guaranteed part.
•
Check that the door seals are in good condition. It is often necessary to clean the door seal. Using
unsuitable cleaning products can cause premature ageing of the seals. Certain rules must therefore be followed: whenever you clean the seal, always rinse off
any cleaning product with clear water. All traces of cleaning product must be removed from the seal. EuroCave only recommends using a mild soapy solution.
If this proves insufficient, it is possible to occasionally use an ethanol-based solution, provided that the concentration used is less than 10% and that the seal
is then rinsed thoroughly with clear water.
8/ OPERATING FAULTS
Possible incidents
Causes
The temperature
The icon
displays
has not dropped
below the limit of
±4°C / 39°F
Operating faults
The icon
is still displayed even
though I have performed the corrective
action above
Open door alarm Ensure the door is closed properly.
The icon
displays
The relative
The icon
flashes
humidity rate
falls below 65 %
for more than 72
hours
The apparatus cannot lower the humidity
to the desired level.
Carbon filter
The icon
displays
alarm
Temperature
The icon
displays
sensor defect
alarm
/
The wine cabinet does not switch on.
If your appliance appears to be functioning abnormally, contact your EuroCave dealer.
18
GB
1
2
Your appliance is equipped with a frost prevention
device to protect you in the event of a cold circuit
failure.
Corrective action
Check the door is closed properly.
Check the condition of the door hinge.
If you have placed a large number of bottles in your cabinet in the past few hours,
wait a short while then check the temperature again..
If the alarm persists, contact your EuroCave dealer.
Disconnect the cabinet and contact your EuroCave dealer.
•
Add a glass of water on the humidity cassette (see chapter 6, § IV).
•
In order to obtain the time interval for adding water, count the number of days
between the 1st day when water was added and the day when the pictogram was
displayed.
After a few hours the icon will go out.
•
Empty the cabinet, remove the humidity cassette and clean the tank.
•
Remove the tube positioned on the bottom of the tank. The humidity will be
directly removed from the apparatus.
•
Adjust the level of humidity to 75 % but do not install the pozzolana cassettes
or replace them with new ones.
Call the EuroCave dealer is the problem persists despite these different actions.
Replace the carbon filter (see chapter 6, § VI).
Contact your EuroCave dealer.
Contact your dealer/EuroCave after-sales service.
9/ TECHNICAL FEATURES AND ENERGY DATA
Compact 59
Height
Width
mm
mm
1 température
5059V-V3
830
595
5259V-V3
1790
595
Multi-températures
5059S-V3
830
595
5259S-V3
1790
595
Setting accuracy: +/-1°C/ 2°F, Display accuracy: +/- 1 °C/ 2 °F.
Technical features and data relating to European regulations on power consumption
Reference
Type of door
Energy
Annual energy
efficiency
consumption AEc
rating
(kWh/year)
1
230V-50Hz
(R600a gas)
1 température
5059V V3
Glass door
A
132
5259V V3
Glass door
A
157
5059V V3
Glass door
A
132
5259V V3
Glass door
A
157
Multi-températures
5059S V3
Glass door
A
132
5259S V3
Glass door
A
157
5059S V3
Glass door
A
132
5259S V3
Glass door
A
157
1- Only concerns 230V-50Hz models (R600a gas). 2- Power consumption calculation based on the result obtained over 24 hrs in standard test conditions (25°C/77°F). Actual power
consumption depends on the appliance's location and operating conditions.
This appliance is intended exclusively for wine storage.
Category of all models: 2
Climate class: Our appliances are designed for use at an ambient temperature of between 10°C and 32°C (50°F and 90°F) (Class SN). Nevertheless, refer to the technical properties tables
for the optimal performance levels of your product..
These appliances cannot be built-in.
3- Red serving temperature
Standards
Your product complies with the following standards:
1- S
- Directive 2006/95/CE
afe ty
Standards
EN60335-1: Version 5 - 2010 +A1 + A2 + A11 + A12 + A13
EN60335-2-24: Version 7 - 2010 + A1 + A2 + A11
2- eMC - Directive 2004/108/CE
Standard
EN55014-1/2
3- e
- Directive 2010/30/EU
nvironM e nt
Regulation
1060/2010
Depth
Weight when
Recommended temperature range
mm
empty kg
T° mini °C / °F
570
42
0 / 32
585
65
0 / 32
570
40
12 / 54
585
63
12 / 54
The use of glass doors can alter the performance of your wine
cabinet in some extreme temperature conditions.
Useful
Acoustic emissions
volume
(dB(A))
(liters)
2
1 1 5 V- 6 0 H z
230V-50Hz
1 1 5 V- 6 0 H z
(R134a gas)
(R600a gas)
(R134a gas)
-
111
42
42
-
318
37
37
-
111
42
42
-
318
37
37
-
119
42
42
-
325
37
37
-
119
42
42
-
325
37
37
R600a
Depending on the country, EuroCave
wine cabinets may contain flammable
refrigerant gas (R600a: ISO BUTANE).
T° max °C / °F
30 / 86
30 / 86
30 / 86
30 / 86
19
GB