U S E R M A N U A L
DESCRIPTION OF THE UNIT
!
Model plate with sleeves
@
Centric quick lock
#
Sideshift adjusting screw
$
Incisal pin
%
Incisal guidance pin
^
Incisal guidance pin locking screw
EN
&
Magnet
*
Lower adjusting plate locking screws
DESCRIPTION OF THE PRODUCT
The Artigator comprises 3 parts for articulating dual
arch impressions and fabricating a precise sectioned
working model in one single process. The Artigator
concentrates on functioning efficiently and straight-
forward, timesaving handling. The centric quick lock
and sideshift function enable the centre position to be
reproduced exactly. Extra powerful magnets in the upper
and lower members retain the pin plates. All components
are manufactured and assembled highly precisely.
The Artigator is robust, will not distort and is guaranteed
to be long lasting.
HANDLING
CENTRIC QUICK LOCK
a) Opening the centric quick lock
Place your thumb on the grooved area and press
the lock upwards. The head of the condyle is then
loose in the condylar path and the upper member
of the Artigator can be moved backwards. The lock
prevents the upper member from falling out.
b) Removing the upper member of the Artigator
Open the centric quick lock, push the upper member
back fully and hold it in this position.
Use your other hand to press the lock down
(close the centric). The upper member of the
Artigator can then be removed backwards.
6
PROCEDURE
Replace the incisal guidance pin with the incisal pin (2).
Lock the sideshift adjuster and position the impression
correctly on the Artigator where possible, the space
between the tray and Artigator should be the same
all round. The pin plate sleeves are easily positioned
properly (3). lf the space between the pin plate and
Artigator is too narrow, carefully trim any excess
material off the impression with a scalpel. Remove the
pin plates from the Artigator and spray them and the
sleeves with the separating agent supplied. (4) Coat
them thoroughly with separating agent and allow
it to take effect. Then blow the surface dry. Cast the
impression as usual with type 4 high strength dental
stone (5). Fill the first pin plate with a sufficient amount
. Fill the first pin plate with a sufficient amount
. Replace the pin plate on
of stone vibrating it gently (6). Replace the pin plate on
the Artigator and wait until the stone is slightly viscous
the Artigator and wait until the stone is slightly viscous
(7). Locate the dual arch impression tray correctly
. Ensure that a small
on the pin plate of the Artigator (8). Ensure that a small
amount of stone remains on the edge of the pin plate
sleeve (app. 8 mm height) so that later on the dental
arch releases easily from the pin plate. Allow the stone
to set and cast the opposite side using the same
procedure. Wait until this stone is also viscous and close
procedure. Wait until this stone is also viscous and close
the Artigator. lt is advisable to turn the Artigator upside
the Artigator. lt is advisable to turn the Artigator upside
down on the bench top for this procedure (9). Once
the stone has set fully, remove the impression from the
the stone has set fully, remove the impression from the
Artigator and release it carefully (10). To facilitate
releasing the model from the model pin, place it (pin
plate upwards) in the sleeve and tap it gently on the
bench top (11 - 14). Trim the dental arch carefully
(except the bottom) and section as required with a saw
(15 - 16). Complete casting the model as shown in
pictures (17 - 19).
lmportant:
Adhere strictly to the stone manufacturer's
mixing ratios to ensure that the optimum expansion
mixing ratios to ensure that the optimum expansion
values are attained (to achieve optimum friction
between the stone and pin plate). Epoxy resins must
between the stone and pin plate). Epoxy resins must
not be used.

MAINTENANCE AND CLEANING

.
The Artigator is maintenance-free. As the Artigator
The Artigator is maintenance-free. As the Artigator
is a high precision unit, it must only be steam-cleaned
is a high precision unit, it must only be steam-cleaned
(e.g. with an AmannGirrbach–Steamer). It should be
(e.g. with an AmannGirrbach–Steamer). It should be
cleaned as gently as possible and without using solvents.
cleaned as gently as possible and without using solvents.
The Artigator wilI function long term without the use
The Artigator wilI function long term without the use
of lubricant. Do not allow it to contact powerful acids or
of lubricant. Do not allow it to contact powerful acids or
clean it in an ultrasonic unit.
clean it in an ultrasonic unit.
GUARANTEE
Thank you for purchasing this high quality Artigator.
Thank you for purchasing this high quality Artigator.
Il was developed and manufactured in accordance with
Il was developed and manufactured in accordance with
the highest quality standards.
the highest quality standards.
We therefore guarantee the workmanship and perfect
We therefore guarantee the workmanship and perfect
condition of the Artigator for 12 months. This guarantee
condition of the Artigator for 12 months. This guarantee
does not cover expendable components.
does not cover expendable components.
lf an inspection of the Artigator indicates that it
lf an inspection of the Artigator indicates that it
has been tampered with, operated incorrectly or the
has been tampered with, operated incorrectly or the
instructions not adhered to, the guarantee is void.
instructions not adhered to, the guarantee is void.
Damages are limited strictly to free repair or
Damages are limited strictly to free repair or
replacement of the unit. We expressly disclaim liability
replacement of the unit. We expressly disclaim liability
for incidental and consequential damages.
for incidental and consequential damages.
U S E R M A N U A L
!
WARNINGS AND SAFETY
INFORMATION:
The Artigator was developed for use in dental
practices and laboratories. It must be installed and
operated as described in the instructions.
The manufacturer accepts no responsibility for
damage which occurs if used for other purposes or
if not used according to the instructions .
In addition, if the intended application is not
listed in the user's manual, the user is obliged to check
personally in advance that the unit is suitable for
this purpose.
Warning:
For use in dental practices by qualifi ed, trained
and skilled persons only.
Technical Data:
Weight:
0,5 kg
Condyle radius:
17,5 mm
Inclination of condylar guidance:
30°
Interior height:
66 mm
Bennett angle:
12°
Accessories / Components:
Order no.:
218941
Base plate blue, 50 pcs.
218933
Sleeves
218948
Seperator spray, 100ml
218949
Seperator spray, 1l
(for refill of spray bottle)
Package contents:
Order no.:
218950
Artigator incl.
218941
Base plate blue, 2 pcs.
218933
Sleeves, 3 pcs.
218936
1 incisal guidance pin
218935
1 incisal pin
User Manual
EN
7