MAINTENANCE AND SERVICE

4.
Maintenance and Service
4.1.

Inspection and Maintenance

General instructions
To maintain readiness for use, the SavOxCap 60 must be inspected regularly,
checked for integrity and, if necessary, cleaned (do not use metal brushes!).
Other maintenance measures are not required.
As the unit contains a chemical which is sensitive to moisture, it is packed in an
airtight container and is sealed at the factory.
The frequency of inspection depends on the device load ( inspection
schedules).
For used and/or opened units, the chemical canister must always be replaced,
reuse is not permitted.
Internal checks and any repairs to the unit are to be carried out by the MSA
Customer Service.
For return of used or opened units for repair, observe the following:
Pack the units and components in the device containers only after they have
cooled down and are dry.
No organic substances must enter the chemical canisters (e.g. solvents, oils,
etc.).
Observe transport instructions ( Chapter 5).
Schedules
Attention!
The following details for inspection and maintenance apply only to
unused stationary stored units.
1)
Intervals
Every 6 months
2)
Annual
After 10 years
1) The criterion for the intervals is the date of manufacture (month/year) on the container.
2) It is recommended that you make a service contract with MSA Customer Service.
12
Inspection measures
Visual check of the seal on the container
Tightness test ( section 4.2)
Replace unit, use no longer permitted