3.
General Description
3.1.
Use
The Minilift F is used for pumping household sewage containing faeces. Installation of toilet, plus sink and urinal
or bidet, or shower in rooms below the backflow level of the sewer (rooms in the basement or cellar), or without
adequate slope to the next sewage collection pipe. The Minilift F is suitable for waste disposal for up to three sa-
nitation units. The stainless steel cutting mechanism of the built-in pump reliably crushes faeces and toilet paper.
Therefore, a diameter of 1" is sufficient for the pressure line to the next sewage pipe. Direct connection to the
toilet allows installation behind the toilet with minimal space required.
The ifting station is in accordance with the DIN EN 12050-3: 2015 standards.
It is essential to ensure that no sanitary products such as tampons, sanitary napkins, condoms, etc., as well as
non-cuttable materials such as glass, wood, metal (razor blades, bottle caps), etc. enter the wastewater, since
they are not crushed by the cutter, will remain in the collection container and may block the pump under certain
circumstances. Avoid dumping very fatty wastewater into the lifting system.
The flow rate in the pressure line must be at least 0.7m/s.
3.2.
Use types
The sewage lifting systems are designed for intermittent duty:
• Minilift F S3 30%
3.3.
Structure
The lifting systems are made of a non-rotting, water, gas and odour-proof plastic container with a single-stage
rotary pump.
The containers have different connections:
two-sided inlet
DN40 with back-
flow flap
Minilift F
X
Technical data
Power consumption
Voltage
Rotational speed
Nominal current
Protection Class
Weight
Container volume
Switching volume
GENERAL DESCRIPTION
lateral pressure
connection with
25mm ball back-
flow preventer
X
Minilift F
650 W
230V / 1Ph
2900 U/min
2,6 A
IP44
8 Kg
11 l
4 l
30/120
upper inlet basin
WC inlet
DN40
DIN1387 Form A
DIN1388 Form A
-
X
Ventilation with
activated carbon
filter
X
2016/04