Troubleshooting
Device does not switch off
1.
Run through the pressure relief procedure, leave the bypass switch open, and set the ON/OFF switch to OFF.
2. Remove the cover of the control unit so that the control board status light can be viewed (if present).
Troubleshooting procedure
Connect an analogue manometer between
the device and the material hose; start
up the device. Is the maximum pressure
exceeded?
Yes
Disconnect the pressure sensor from the
control board. Does the motor stop run-
ning?
Yes
Faulty pressure sensor. Replace and test
with a new sensor.
Original instruction
Check fittings for leaks. See Troubleshoo-
No
ting paint stage
No
Replace control board.
202