Only switch off the power for the receiver to be reset.
Place the blind in the intermediate position (if possible).
Switch off the power supply for 2 seconds.
Switch the power supply back on for 5 to 15 seconds.
Switch off the power supply for 2 seconds.
Switch the power supply back on: the blind starts to move
for a few seconds.
If the blind is at the upper or lower end limit, it will move
Hold down the PROG button for 7 seconds: the blind will
move once then again a few moments later. The actuator
Repeat the procedures from the "Commissioning" section
10. TECHNICAL DATA
Power supply
Index protection rating
Maximum load
Maximum operating time after a control
command.
Radio frequency
Operating temperature
Maximum number of associated control
points and sensors
control function
Operating mode / action
Pollution degree
Rated impulse voltage
Ball hardness test temperature
EMC Emissions-Tests
Attachement
This control is an electrically and manually operated in-line cord control.
© 2013 Somfy SAS. All rights reserved. 02/2013
5 sec.
ON
15 sec.
ON
220 - 240 V / 50 Hz
IP 54
250 VAC / 3A
4 min
- 30 °C à + 70 °C
9
A
Type 1
2
2,5 kV
75° C
UAC = 230 V AC IAC = 0.2 A
Type Y
OFF
2 sec.
OFF
2 sec.
my
71