6. COMMISSIONING

The guide only describes commissioning using a Situo mobile io VB type Somfy io local control point
which provides greater precision when tilting the slats.
For commissioning using any other io control point, refer to the corresponding guide.

6.1. Identifying setting steps already completed

Only one motor should be powered at a time.
Switch on and follow procedure "a" or "b" depending on the
reaction of the blind:
The linear travel is set and no Somfy control points have
been programmed.
control point".
or
b) The blind does not move
Press the Up or Down button and follow procedure "c" or
"d" depending on the reaction of the blind:
c) The blind still does not move
The linear travel is not set and the Somfy control point has
not been programmed.
control point".
or
d) The blind raises or lowers completely by pressing
and holding the up or down button.
The linear travel is set and the Somfy control point has
been programmed.
Go to the section entitled "Operation".

6.2. Pre-programming the Somfy io local control point

Press the Up and Down buttons simultaneously.
The blind
pre-programmed to the motor.
© 2013 Somfy SAS. All rights reserved. 02/2013
Programming
control point
c
d
or
Pre-programming
the Somfy io local
control point
Operation