GSM Receiver
Delete all the telephone numbers in the memory.
Code to be sent
#PWdpassword#Whl99d
free access. All telephone will call have access, even those which are not memorised.
Code to be sent
#PWdpassword#aCm0(zero)
Controlled access (default setting). Only memorised telephone numbers have access.
Code to be sent
#PWdpassword#aCm2
This resets the receiver to the factory settings.
Note: the telephone numbers stored in the memory are not deleted.
Code to be sent
*rEst#password
Code to be sent
#PWdpassword#Edi?

usE

A call (from a memorised telephone number) to the receiver SIM card can control the automatic device.

tEChNiCal data

Power supply
Operating temperature
OUT1
Index protection rating
Band
Maximum number of telephone numbers which can be memorised
Gsm
SIM type
Aerial
standby consumption
24V ---
24V ~
4
Example of sms to be sent
#PWd123456#Whl99d
access mode
Example of sms to be sent
#PWd123456#aCm0
Example of sms to be sent
#PWd123456#aCm2
resetting the card
Example of sms to be sent
*rEst#123456
Checking and updating the software and the device
Example of sms to be sent
#PWd123456 #Edi?
24V --- ~ + -10%
-5°C to +50°C
NO contact ((max. 120V ~ / 24V --- 1A)
IP44
GSM/GPRS tri-band 900/1800/1900 Mhz
99
3V/1.8V
3.5 dB - 5 dB
< 60 mA
< 120 mA
Example of sms received
dEllall-oK
Example of sms received
aCm-off
Example of sms received
aCm-oN
Example of sms received
rEst-oK
Example of sms received
software release time:<WT-009_LIA>2009/8/08/10:45
HW:1.0SW:1.0MW:2.3>