PROBLEMS AND SOLUTIONS

PROBLEM
CAUSE
Gas bottle pressure regulator is
closed
Empty gas bottle
Pilot light does
not burn
Blocked gas nozzle
Air in system
Loose connection
Dirt around pilot light
Loose connection
Pilot light still
Bad thermocouple
does not burn
Gas leak in pipe
Low gas pressure, bottle almost
empty
Low gas pressure, bottle almost
empty
Blocked nozzle
Control button off
Burner does not
Bad thermocouple
go on
Pilot light not assembled correctly
Patio heater is not installed
properly or is not situated in a
suitable place
CE STATEMENT
The undersigned: Euromac bv., Kokosstraat 20, 8281 JC Genemuiden
hereby declares that the product below
known under the brand
type
power
fulfils the European directive 2009/142EEC for devices with gaseous fuels and corresponds to the
following requirements:
BSEN 14543:2005+A1:2007
Genemuiden, 22 March 2012
W.J. Bakker, Gen. Dir.
- 23 -
gas-powered patio heater
EUROM
THG12000 (gas) & THG12000RVS (gas)
12.0 kW
SOLUTION
Open it
Replace gas bottle
Clean it
Aerate it
Check and tighten
Clean
Check and tighten
Replace
Check and repair or replace
Replace gas bottle
Replace gas bottle
Clean it
Turn it on
Replace
Install pilot light unit properly
Check location and installation