Removal Of Parts For Cleaning/Sanitizing - Manitowoc SM Serie Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 4
Step 9 Mix 1 oz (2 tablespoons) sanitizer with 2 gal of
warm water.
Model
Sanitizer Amount
SM50
1 oz. (30 ml)
Step 10 Use 1/2 of the sanitizer/water mixture to
sanitize all removed components. Use a cloth or sponge
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/solution. Rinsing is not required.
Step 11 Use the other 1/2 of the sanitizer/water solution
and a sponge or cloth to sanitize the inside of ice bin.
Sanitize inside of door, door gasket, bin, top of
evaporator and evaporator bucket. Rinsing is not
required.
Step 12 Replace all removed components.
Step 13 Prepare 1/2 oz (1 tablespoon) of undiluted
Manitowoc Sanitizer.
Step 14 Reapply power to the ice machine, then press
the Clean switch.
Step 15 Wait 3 minutes until the Clean light flashes,
then add the prepared Manitowoc Sanitizer by lifting the
water shutters and pouring directly into the spray area.
The ice machine will automatically time out a ten minute
sanitizing cycle, followed by eight rinse cycles, and stop.
The Clean light will turn off to indicate the sanitizing
cycle is complete. This entire cycle lasts approximately
30 minutes.
NOTE: The ice machine will automatically continue from
the previous point before the clean cycle was initiated.
A. If the ice machine was in the ice making cycle,
the control board will start ice making again.
B. If the ice machine was in the off cycle, the
control board will turn off.
Part Number 040001361 05/10

REMOVAL OF PARTS FOR CLEANING/SANITIZING

1. Turn off the electrical and water supply to the ice
Water Amount
2 gal (8L)
Disconnect electric power to the ice machine before
proceeding.
2. Remove all ice from the bin.
3. Remove the components that must be cleaned and
Wear rubber gloves and safety goggles (and/or face
shield) when handling Cleaner or Sanitizer.
4. Soak the removed part(s) in a properly mixed
Solution Type
5. The cleaner will foam; once the foaming stops use a
Do not immerse the water pump motor in the
cleaning or sanitizing solution.
6. Thoroughly rinse all the parts with clear water.
7. Soak the removed parts in a properly mixed solution
8. Use a soft-bristle nylon brush, sponge or cloth (NOT
9. Use the sanitizing solution and a sponge or cloth to
10. Rinsing is not required when using Manitowoc
11. Install the removed parts.
12. Turn on the water and electrical supply.
machine.
!
Warning
sanitized. See the following pages for removal
procedures for these parts.
Warning
!
solution of cleaner.
Water
Cleaner
1 gal. (4 l)
Sanitizer
2 gal. (8 l)
soft-bristle nylon brush, sponge or cloth (NOT a wire
brush) to carefully clean the parts.
! Caution
of sanitizer for 5 minutes.
a wire brush) to carefully sanitize the parts.
sanitize (wipe) the interior of the ice machine and
bin.
Sanitizer.
Maintenance
Mixed With
8 oz (240 ml) cleaner
1 oz (30 ml) sanitizer
17

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Sm-50a

Table des Matières