INSTALLATION
Troubleshooting
7.
Troubleshooting
Problem
Cause
The appliance does
Temperature set too low
not heat up.
on the appliance.
No power supply.
Overheating. The high
limit safety cut-out has
tripped.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).
INSTALLATION
8.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
8.1
General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
WARNING Electrocution
Install the appliance in such a way that control equipment
cannot be touched by a person in the bath or shower.
Material losses
- Fit the appliance to a vertical wall that is heat-resist-
ant to at least 90 °C.
- Maintain the minimum clearances to adjacent ob-
jects.
- Never install the appliance directly below a wall
socket.
Note
The power cable must only be replaced (for example if
damaged) by a qualified contractor authorised by the
manufacturer, using an original spare part.
8.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
www.stiebel-eltron.com
remedy
Check the selected room
temperature. Adjust if nec-
essary.
Check the RCD and the fuse/
MCB in the fuse box.
Remove the cause. After
cooling down for a few min-
utes, the appliance restarts
automatically.
9.
Appliance description
9.1
Standard delivery
The following are delivered with the appliance:
- 1 wall mounting bracket
- 1 fixing bracket
9.2
Accessories
CON 15-30 S | CON 15-30 ZS:
- Towel holder
10. Preparations
10.1 Minimum clearances
a
b
≥100
≥250
≥10
11. Installation
f The correct hole spacing for the wall mounting bracket is
f
provided in the dimensioned connection drawing (see chap-
ter "Specification").
f Secure the wall mounting bracket with suitable fixing mate-
f
rials. The horizontal and vertical slots in the wall mounting
bracket enable alignment if drilled holes are not completely
accurate.
f Hook the appliance into the wall mounting bracket.
f
f Secure the appliance with the mounting bracket and one
f
screw to prevent unintentional unhooking. Hook the fixing
bracket into the back panel of the appliance from below.
Towel holder (CON 15-30 S | CON 15-30 ZS)
f Guide the towel holder from above over the wall mounted
f
appliance.
f Insert the left and right-hand ends of the towel holder into
f
the mounts provided for this purpose in the back panel of the
appliance.
CON 10-30 S | CON 10-30 ZS |
a
≤ 150
b
≥ 250
a
b
≤ 200
≥ 500
≥100
15