OPerATION

Cleaning, care and maintenance

5.4.3 Parameter
You can call up the following parameters:
display
description
P1
Room temperature offset
P2
Time format
P3
Temperature display units
P4
Reset the time programs (Pro1, Pro2, Pro3).
P5
Reset relative heating time
To change the value of a parameter, use "+" and "–" to call up the
relevant parameter. Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with "+" and "–". Press "OK" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a dif-
ference between displayed actual temperature I1 and the room
temperature you measure. To compensate for this difference, a
room temperature offset of ±3 °C can be set via parameter P1.
Example: The appliance indicates I1 = 21.0 °C. You have measured
a room temperature of 20.0 °C. There is a difference of 1.0 °C.
f To compensate for the difference, select an offset of P1 = -1.0.
P2: Time format
Parameter P2 allows you to specify whether the time is displayed
in the 12 hour or 24 hour format.
P3: Temperature display units
Parameter P3 is used to specify whether the room temperature is
displayed in degrees Centigrade [°C] or Fahrenheit [°F].
P4: Reset time programs
Activating parameter P4 resets all time programs (Pro1, Pro2,
Pro3) to the factory setting.
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating
time (I2).
6.
Cleaning, care and maintenance
The appliance contains no user serviceable parts.
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning prod-
ucts. Avoid abrasive or corrosive cleaning products.
22
| CON Premium | CON Premium U
7.

Troubleshooting

Problem
Room does not get
Options
warm enough. Ap-
±3 °C | ±5 °F
pliance does not get
12 h | 24 h
hot.
°C | °F
on | off
on | off
Room does not get
warm enough al-
though the appliance
is hot.
The room gets too
hot.
The "Heating active"
symbol flashes. The
appliance does not
heat up.
Window open de-
tection does not
respond.
"Adaptive start" func-
tion does not work as
required.
Appliance is in "FP"
program but does not
respond to external
input.
"Err" or "E..." is dis-
played.
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).
Cause
remedy
Temperature set too low
Check the selected room
on the appliance.
temperature. Adjust if nec-
essary.
No power supply.
Check position of the ON/OFF
switch, RCD and fuse/MCB in
your fuse box.
Overheating. High limit
Eliminate the cause (dirt or
safety cut-out limits
obstructions at the air intake
heating output.
or discharge). Observe mini-
mum clearances.
Heat demand of the room
Remedy heat losses (Close
is higher than the appli-
windows and doors. Avoid
ance output.
constant venting.)
Appliance temperature is
Check the selected room
set too high.
temperature. Adjust if nec-
essary.
The electronic room
Wait until the end of this
temperature controller
period between two start
restricts the duration
times.
between two start times
to at least 10 minutes.
Heating remains off until
this period has expired;
the "Heating active" sym-
bol flashes.
Appliance does not detect
Wait a while after making
a pronounced tempera-
settings on the appliance,
ture drop when venting.
until the room temperature
(Window open detection
has fully stabilised.
requires a previously sta-
ble room temperature.)
Avoid obstructions to air
changes between appliance
and indoor air.
Install the appliance in direct
proximity to a window.
Air the room by fully opening
a window.
Manually switch the appli-
ance to standby mode for the
duration of venting.
The set room temper-
Change the set room temper-
ature is set lower than
ature to 15 °C or higher.
15 °C.
Window open detection
Switch on window open
is not enabled.
detection in the standard
menu.
This function is only
Use the time programs for
effective with a time pro-
optimised heating conven-
gram activated.
ience.
Severely fluctuating room
Wait a few days for the be-
temperature or the appli-
haviour to stabilise.
ance learning procedure
has not been completed.
"Adaptive start" function
Switch on the "Adaptive
is not enabled.
start" function in the stand-
ard menu.
When the appliance does
Check external control unit
not detect a signal at the
and its settings. Wiring must
external input, it heats in
be installed correctly and
comfort mode.
with correct polarity.
Internal fault detected.
Notify the qualified con-
tractor.
www.stiebel-eltron.com