SATA LAB Automatic Gun Operating Instructions
EN
■ Nozzle head [1-8] (rotates in steps of 90°)
■ Air cap (positioned in steps of 45°, fully variable positioning in SATAminijet)
■ Fluid tip
■ Gravity flow cup connection piece [1-15]
Spray gun body
■ Gun body [1-9]
■ Round fan control [1-14] fixed to ideal value, not adjustable
■ Flat fan control [1-6] with scale washer [1-5]
■ Material flow control [1-2] with scale on gun body [1-13] and scale ring [1-3]
■ Fastening bolt [1-1]
■ Control air connection [1-11]
■ Spraying air connection [1-12]
8.

Assembly

Loose screws can cause damage to parts or result in malfunctions.
→ Tighten all screws by hand and check that they are screwed tight.
Attention!
All automatic guns have integrated pre-/post-air control.
The automatic gun is fixed in the spraying system with a fastening bolt.
The air supply then has to be connected. The air supply connection el-
ements are not included in the scope of supply and can be ordered on
request.
8.1. Mounting with fastening bolt
Screw fastening bolt [3-1] in fastening thread [3-2]. Secure with Loctite
270.
■ Use fastening bolt to fix the automatic gun to the fastening system of the spray-
ing system.
■ Connect control air to the control air connection [1-11] of the automatic gun.
■ Connect spraying air to the spraying air connection [1-12] of the automatic gun.