Maintenance; Fault Finding; Time Mode - SKF TMBH 1 Mode D'emploi

Masquer les pouces Voir aussi pour TMBH 1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
5

MAINTENANCE

To ensure optimal performance and lifetime of the heater protect the unit against
physical misuse, high humidity and direct contact with water.
Avoid impacts against the clamp. The ferrite core especially is sensitive to these
types of shocks.
Do not overload the spring mechanism on the clamp.
Make sure the the ferrite poles are clean and that the clamp closes perfectly.
5.1

Fault finding

In case of certain malfunctions, the operator will be guided by an error code
appearing on the display:
Display
E 00 E
E 01 E
E 02 E
E 03 E
E 04 E
E 05 E
E 06 E
E 07 E
E 08 E
E 09 E
12
Fault
Electronic failure
Electronic failure
Electronic failure
Overheating in housing
Selected time / temperature
out of range
Temperature increase below
1 degree per 15 s.
Temperature probe not
connected or defect
Temperature above 200 °C
(392 °F)
Clamp is open
Clamp not plugged in or
broken
Action
Return to SKF for repair
Return to SKF for repair
Return to SKF for repair
Wait for unit to cool down
Adjust time / temperature
setting
Check that the probe is
properly attached to the
workpiece or change to

TIME MODE

Check the probe
Stop heating
Close the clamp
Plug in or change the
clamp
SKF TMBH 1

Publicité

Table des Matières
loading

Table des Matières