The SQUEEZING TRAY and the BLADE are removed by unscrewing the nuts from the
SQUEEZING TRAY SHAFT and pulling out sideways. Also unscrew the GREEN BALLS
inside the SQUEEZING TRAY (Fig. 21); under each one are one washer, be careful not
to lose them! When cleaning TAKE SPECIAL CARE WITH THE BLADE (Fig. 5), as it is
very sharp and you may cut yourself.
-
To remove the CUPS, unscrew the FASTENING NUTS slightly and push them down and
pull outwards. They will become lose and can be easily removed.
-
Remove the fallen peel. (Scheme 1, No. 15).
-
Wipe the FRONT and ROOF of the squeezing machine with a cloth and soapy water.
Assembly:
-
Screw the BALLS onto the SQUEEZING TRAY. Be careful to replace the washer
beforehand and to screw the BALLS tightly into position.
-
Check that the BLADE has its PEEL EXTRACTING BANDS correctly positioned (the
Extracting Band parallel to the FRONT of the machine must be above the perpendicular
Extracting Band see (Fig. 22)) and place the BLADE into the SQUEEZING TRAY.
Assemble the unit (SQUEEZING TRAY + BLADE) simultaneously on the three
machine Shafts. (Fig. 23). Never assemble the BLADE onto the tray afterwards!!
When it reaches the bottom, fit the BLADE lip onto the front guide. (Fig. 24).
-
Place the Cups onto the Shafts and tighten using the nuts.
-
Before restarting the machine, observe:
That the Squeezing Tray and the Blade are well fitted and screwed in tightly.
That the BLADE is well fitted and in a horizontal position.
That the Cup Nuts are well tightened.
-
In the event of the BLADE, the Squeezing Tray, the balls or the cups not being well placed,
damage may be caused to these parts and even to the inside of the machine. (Problems
not covered by the guarantee, these being operator faults).
WASTE BAG. - The waste bag must be replaced unless every 48 hours. (Fig. 25)
MACHINE DOOR.-To keep the door rubber seal in good condition, it is very important to
clean it frequently. Also remember to keep clean the lower part of the machine's door to
prevent proliferation of unwanted insects.
WATER CONTAINER. - Empty the WATER CONTAINER (Scheme 1 No. 17) and place it
back. Place the WATER LEVEL SENSOR above the mouth and the EVAPORATOR
DRAIN HOSE and HYDROTUBE in its holes.
DRIP GRILLE. - Unscrew the plastic nut and pull backwards to remove the Drip Grille. (Fig.
26). The Drip Tray can be unscrewed should it require thorough cleaning.
EXTERIOR FILTER and EXTERIOR FILTER TRAY. - Loosen the handles fastening this
unit, (Fig. 27) pull the right hand side upwards and then to the right until completely loose.
Remove the filter and its tray, paying attention to the original position. After washing,
replace it and tighten the handles slightly. Attention! Never use hot water to wash the
exterior filter tray, it will get distorted!
FEED ROLLERS. - When you want to wash the Feed Rollers, these can be removed from
their housing. To do so, pull the left hand side upwards and then to the left. (Fig. 28 and
29). If the coils are removed, pay attention to their position because each roller has one on
each side.
IMPORTANT: Refs. 1003005A left channel, 1003007A right channel, 1003024B front
cover, 1003025 exterior filter tray and 1004023 lower plastic lid, are made from heat-
formed plastic. They must not be subjected to temperatures higher than 40°C, so they
should never be washed in very hot water or in a dishwasher; if they are deformed by heat,
the warranty will not apply.
1.4. ADVICE FOR USE
Do not use the gap in the hopper for storage (Fig. 37).
Make sure not any objects block the drainage tube. (Fig. 38)
Make sure the oranges fit easily into the cups chosen for squeezing, because if the cup
is too small it will pinch the peel and draw out oil which will make the juice taste bitter.
To get the maximum amount of juice, it is better for the cups not to be too much bigger
than the oranges being used.
Clean the photocell lenses regularly.
25