UK │ 12. Fault rectification, 13. Spare parts
Fault
Cause, Measure
Impeller blocked.
Fan does
Should only be carried out by
not switch
a trained electrician: Remove
on.
cover [6]. Unlock internal grille
[5.1] or internal shutter [5.2] using
locking hooks (see arrow) and
remove. Check impeller and clean
if necessary.
Fault
Cause, Measure
Fan does not
Overrun time
switch off.
(max. 25 minutes).
Wait for the overrun time and
reduce if necessary,
 Chapter 9.5.
Motor's
Motor too hot.
thermal
Wait until the motor has
overload
cooled. Cool-down time can
protection
be up to 10 minutes. Unit
switches the
switches back on automa-
fan off.
tically after cooling.
Lamella do
1) Lamella very dirty or
not open or
blocked.
close
Clean lamella. Check whether
for K units.
there is anything between the
lamella. Remove if necessary.
2) Check whether the wiring is
correctly carried out refer to
diagram 1 (high level),
page 34. Bridge terminal 1
and 2.
Fan does not
A high-impedance voltage
switch off
applies against terminal L1
or
with a control switch negative
fan switch on
glow lamp, parallel installed
accidentally.
wires (mutual induction) or
transformers respectively
other electrical parts.
22
Recommendation: Connect a
X2-capacitor (220 nF/250 V)
against neutral lead.

13. Spare parts

Spare parts may only be sourced
from and fitted by a specialist
installer.
Designation
Sensors
SE ECA 100 ipro H
SE ECA 100 ipro F
SE ECA 100 ipro B
Covers
ABD ECA 100 ipro 1
ABD ECA 100 ipro 2
ABD ECA 100 ipro 3
Electronic covers
ABDE ECA 100 ipro 1
ABDE ECA 100 ipro 2
Circuit boards
PL ECA 100 ipro
PL ECA 100 ipro F/H/B
PL ECA 100 ipro VZC
Flap frames
KR ECA 100 ipro
Should you have any questions
Maico Elektroapparate-Fabrik GmbH
Steinbeisstraße 20
78056 Villingen-Schwenningen,
Germany
Tel. +49 7720 694 445
Fax +49 7720 694 175
E-mail: ersatzteilservice@maico.de
Spare parts can be ordered at:
www.shop.maico-ventilatoren.com.
Article no.
E157.0141.0000
E157.0140.0000
E157.0139.0000
E059.2022.9000
E059.2022.9100
E059.2022.9200
E059.2010.0000
E059.2010.9000
E101.1404.0000
E101.1405.0003
E101.1406.0001
E059.2007.9101

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Eca 100 ipro vzcEca 100 ipro fEca 100 ipro hEca 100 ipro bEca 100 ipro kEca 100 ipro kvzc ... Afficher tout

Table des Matières