UK │ 5. Product information
Unit model
ECA 100 ipro
ECA 100 ipro VZC
ECA 100 ipro F
ECA 100 ipro H
ECA 100 ipro B
ECA 100 ipro K
ECA 100 ipro KVZC
ECA 100 ipro KF
ECA 100 ipro KH
ECA 100 ipro KB
Bold Condition as supplied
●
Standard equipment
4 operating programs available
with optional light switch
VZC and KVZC: Model with start delay
and overrun time.
F and KF: Model with light sensor, start
delay and overrun time. Switch-on intensity
(at fan) min. 30 lux. Switch-off intensity
(at fan) max. 1.7 lux.
H and KH: Model with humidity control
(fully automatic), start delay and overrun
time.
B and KB: Model with motion detector and
overrun time. Without start delay. Monito-
ring range of motion detector horizontal
100°/vertical 82°.
Humidity control function
for H and KH units
Once the fan is installed, it adjusts itself
to the prevailing room humidity (relative
humidity). This humidity value is saved as the
first reference value. The reference value
does not have to be specified manually.
If the relative humidity falls below the reference
value during operation, the newly established
reference value is saved. The lowest possible
reference value is 48 % relative humidity.
16
Start delay
Overrun time
[sec.]
[min.]
0/50/90/120
0/8/17/25
0/50/90/120
0/8/17/25
0/50/90/120*
8/17/25**
0/8/17/25
0/50/90/120
0/8/17/25
0/50/90/120
0/8/17/25
0/50/90/120*
8/17/25**
0/8/17/25
*
** 0 min overrun time available when using an optional
Mains cable
[mm²]
5 x 1,5
5 x 1,5
3 x 1,5
3 x 1,5
3 x 1,5
5 x 1,5
5 x 1,5
3 x 1,5
3 x 1,5
3 x 1,5
Start delay available when using an optional switch
(e.g. light switch).
switch (e.g. light switch).
If the room humidity increases by 7 %, the fan
engages automatically at performance level 1
(78 m³/h).
● If the room humidity increases even
further, the unit switches to performance
level 2 (92 m³/h).
● If there are no further increases, the unit
continues to run at performance level 1
until the humidity again falls below the
saved reference value.
If the humidity falls below the reference value,
overrun mode starts with the set overrun
time. The current reference value is then
saved. If the humidity does not fall below the
reference value within 60 minutes, the unit
switches to the set overrun mode and then
switches off.
H and KH units can also be operated using
the light switch. The set operating program
starts when the light is switched on (
chapter 9.3). The operating program takes
priority over the automatic humidity process.
If the light is switched off, the unit continues
to run until the remaining overrun time has
passed. The automatic humidity process is
then assigned maximum priority again and
controls the unit as described above.
4 operating
Speed
programmes
controllable
●
●
●
●
●
●
●
●