limits ........................................................ 17
8.1 Wall .................................................. 17
8.2 Ceiling .............................................. 17
8.3 Duct.................................................. 17
8.4 Fan ................................................... 18
9.4 Start-up ............................................ 21
11. Cleaning ................................................ 21
14. Dismantling ........................................... 23
15. Environmentally responsible disposal .. 23
16. Wiring diagrams .................................... 36
1. Specialist installer qualification
Mounting may only be carried out by spe-
cialists who have the necessary knowledge
and experience in ventilation engineering.
Only a trained electrician is permitted to
work on the electrics. You are deemed a
trained electrician if you are familiar with the
relevant standards and guidelines, can
competently and safely connect units to an
electrical power supply in line with the
attached wiring diagram and are able to
recognise and avoid risks and dangers
associated with electricity on the basis of your
technical training and experience.
2. Intended use
Fan for extracting air from bathrooms,
toilet rooms, storage rooms, showrooms,
offices, fitness studios, changing rooms and
similar places.
An operation is only permitted with:
● permanent installation inside of buildings.
● installation on walls or ceilings.
3. Safety instructions and warnings │ UK
● air supply via shaft or pipe.
● recessed mounted electrical connection.
Window installation permitted with window
installation kit FE 100/1, connection in flat
channel duct systems permitted with spacing
frame ECA-DR.
This fan is only intended for domestic use
and similar purposes.
3. Safety instructions and
warnings
Indicates a possibly dangerous
situation, which could result in
minor to moderate injuries.
CAUTION
Indicates a possible situation,
NOTICE
which could cause damage to
the product or its surroundings.
The fan unit must not be used in the follo-
wing situations under any circumstances.
Risk of combustion/fire from flam-
mable materials, liquids or gases in
the vicinity of the fan. Do not place
any flammable materials, liquids or gases
near the fan, which may ignite in the event of
heat or sparks and catch fire.
Explosive gases and dusts may
ignite and cause serious explosions
or fire. Never use fan unit in an
explosive atmosphere (risk of explosion).
Risk from operating in single air
extraction systems in accordance
with DIN 18017-3. Fan does not satisfy
the DIN 18017-3 standard. Do not use fan in
systems in accordance with DIN 18017-3.
Risk to health from chemicals or
aggressive gases/vapours. Chemicals
or aggressive gases/vapours may harm
health, especially if they are distributed
throughout the rooms by the fan. Never use
fan to convey chemicals or aggressive
gases/vapours.
Grease and oil vapours from range hoods
may contaminate the fan and ventilation
ducts and reduce efficiency. Never use fan
13