UK │ 9. Installation, operating programs
Night program
● Performance level 2 while room is being
used, performance level 1 during overrun
time.
● J4 open, J5 open
Economy program
● Performance level 1 during operation and
overrun.
● J4 open, J5 bridged
Power program
● Performance level 2 during operation and
overrun.
● J4 bridged, J5 open
20
2. Fit electronics cover.
NOTICE
Danger of short circuits and damage to
unit! Humidity will penetrate if
electronics cover is not used correctly.
Press electronics cover firmly onto
housing such that it is sealed and flush all
the way around. Do not press setting
buttons [11] and [12].
3. Insert electronics cover into housing
recesses I, II and III with the 3 latches
until they snap into place. Press the
electronics cover firmly on to the housing
at the points indicated by the arrows.
4. For unit versions F, KF, H, KH, B and KB,
insert the sensor supplied [9] in the correct
position ( arrow X) in the connector base.
Please note for the versions H and KH
that the membrane located on the flat
side of the sensor housing must not be
exposed to mechanical stress.
5. Fit cover [6].
6. Set start delay and overrun time in
accordance with Chapter 9.5.
7. Fit designer cover [7] ( fold out page,
Fig. B).