Burkert 8696 Guide Rapide page 17

Masquer les pouces Voir aussi pour 8696:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

note!
avoid maladjustment of the controller due to an incorrect
pilot pressure or applied operating medium pressure.
▶ Run X.TUNE whenever the pilot pressure (= pneumatic auxil-
iary energy) is available during subsequent operation.
• Run the X.TUNE function preferably without operating medium
pressure to exclude interference caused by flow forces.
To run X.TUNE, the positioner must be in the AUTOMATIC
operating status (DIP switch 4 = OFF).
note!
Breakage of the pneumatic connection pieces due to rota-
tional impact.
▶ When unscrewing and screwing in the transparent cap, do not
hold the actuator of the process valve but the connection housing.
Fig. 10: Open positioner
Screw off the transparent cap of the positioner to operate the
keys and DIP switches.
Type 8696
Start-up
Transparent cap
Body casing
Connection housing
Actuator
LED 2
LED 1
Fig. 11: Starting X.TUNE
Start the X.TUNE by pressing key 1
While the X.TUNE is running, LED 1 flashes quickly (green).
When the automatic adjustment is complete, LED 1 flashes slowly
(green)
.
6)
The changes are automatically transferred to the memory (EEPROM)
provided the X.TUNE function is successful.
The X.TUNE can also be started via communications software.
5)
if a fault occurs, LED 1 is lit red.
6)
note!
Breakage of the pneumatic connection pieces due to rota-
tional impact.
▶ When unscrewing and screwing in the transparent cap, do not
hold the actuator of the process valve but the connection housing.
damage or malfunction due to penetration of dirt and humidity.
▶ To observe degree of protection IP65 / IP67, screw the trans-
parent cap in all the way.