Defects

8.1

Overview

Problem
Pump does not
prime or
priming time is
very long
Pump output is
not high
enough
Pump is too
loud
Quartz sand is
flushed out of
the filter into
the pool
08/2015
VG 766.2050.052
Possible cause
Pre-filter is not filled with
water
Air is being drawn in
Contamination of the
strainer baskets in the
skimmer and pre-filter
Lid of the pre-filter is not
screwed on tightly
Suction line very high
above water level
Shut-off valve in suction
and pressure line closed
No self-priming pump
being used
Filter dirty
Shut-off valve in the unit
closed
Pipe too long / suction
side too high
Suction line leaks - air is
drawn in
Debris in the pump
Wrong grain size
Filter strainer in the filter
casing damaged
Defects
Solution
Fill to min. height of
inlet connection
Suction line has to
be free of leaks;
Water level up to
middle of skimmer
opening
Clean the strainer
baskets
Tighten
Install non-return
valve
Open the valve
Install a non-return
valve at the suction
side
Backwash
Open
Modify
Seal
Clean the impeller
and casing
Grain size has to
amount to 0.4 -
0.8 mm
Replace
EN 53