Mounting of the individual components

First position the filter casing (2) horizontally in the filter base (1). Align
the filter pump (40) on the filter base (1) so that the connecting tube (4)
can be easily attached to the 6-way valve (10). The pump is screwed
onto the filter pallet (1) using the enclosed screws (30) and the washers
(29). Connect the upper vertical pressure discharge of the pump (40)
with the spiral hose (18) to the valve (10) labelled "PUMP". The length
of the spiral hose (18) can be adapted to the respective pump type. The
hose (4) is fastened with the hose clamps (28) to the valve and the
pump (40) using a screwdriver.
Note: A repeated installation of the spiral hose may cause leakage.
Solution: Wrap Teflon sealing tape around the saw tooth tread design of
the socket connections.
Adapting the spiral hose length to the pump
44 EN
VG 766.2050.052
Pump connection
(Pressure discharge)
18
Valve connection
WG23.400.005-2-P
08/2015