Defects; Preventing Material Damage - aqua technix AQUA AQ 280 Installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Safety
3.8

Defects

Stuck pump
If a pump is stuck and switched on several times repeatedly, the motor
can be damaged. Observe the following points:
3.9

Preventing material damage

Problem
Dry run
Cavitation
Overheating
Blockages
of the pump
Danger of
frost
38 EN
VG 766.2050.052
In case of defects, immediately switch the system off first and then
remove it from operation.
Have all defects repaired immediately.
Do not switch the pump on repeatedly.
Turn the motor
shaft.
Clean the pump.
Possible cause
-
Pipes which are too long
increase resistance
Excessive ambient
temperature (e.g. at
unventilated installation
area)
Pieces of dirt in the
suction line can block
the pump
-
Solution
Do not allow the pump
to run dry
Purge air from pump
and suction line prior
to start-up
Avoid pipes which are
too long
Do not exceed the
permitted ambient
temperature
Do not operate the
pump without strainer
basket
Check how easily
pump rotates before
starting it up or after
longer idle periods
Empty filter system
and pipes before
temperatures drop
below freezing
08/2015

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqua aq 330Aqua aq 400

Table des Matières