6.3

Further measures

Measure
Flushing
the quartz
Cleaning the
Setting the
08/2015
VG 766.2050.052
Explanation
The quartz sand has to be washed out when refilling.
1. 6-way valve (10) in the "RINSE" position
2. Following the start-up of the pump, run water into
3. 6-way valve (10) in the "BACKWASH" position
4. Channel the water into the waste water system for
sand
5. Finally set the valve to "RINSE" for 30 sec
Note:
Too much sand in the filter or too high a pump
performance can lead to losing sand via the sewage
system.
Building dirt or debris have collected in the pre-filter.
Clean the strainer basket of the pump approx. 10
pre-filter
to 15 min after the initial start-up
Set the handle of the valve to "FILTER"
Filter -
operation
Switch the filter pump on
The operating time of the filter depends on the
pool volume, frequency of use, weather and
chemicals
Circulate once to twice per 24 hr, e.g.: Pool
volume: 10 m³, should be circulated twice,
meaning that 20 m³ has to be pumped. The pump
capacity is approx. 6 m³ per hour, so the filter has
filter time
to run for approx. 3 hr
In order to achieve sufficient disinfection on hot
days the filter time has to be increased
Also run the pump on rainy days
Switch the filter pump on
the container and sewage system for
approx. 30 sec
Switch the filter pump on
approx. 2 min. This ensures that quartz sand grit
does not flow into the pool through the nozzle.
Filter is ready for mechanical water treatment
Take the output of the supplied pump into
consideration
Start-up
EN 51