  • Page 1 Original Gebrauchsanweisung Original installation and operating manual Instructions de montage et d‘utilisation originales AQUA Plus Timer OKU Umwälzpumpen, selbstansaugend Swimming pool filter circulation pumps, self-priming Pompes de circulation, auto amorҫantes W91.40.625-P AQUA T E C H N I...
  • Page 2: Instruction De Montage Et D'utilisation Originales

    Original Gebrauchsanweisung Seite 1 Umwälzpumpen, selbstansaugend Original installation and operating manual Page 10 Swimming pool filter circulation pumps, self-priming Instruction de montage et d‘utilisation originales Pompes de circulation, auto-amorҫantes Page 10...
  • Page 3: Sicherheitshinweise

    1. Allgemeines AQUA TechniX GmbH, Neunkirchen am Sand 2. Sicherheitshinweise Mögliche Fehlanwendungen - Einbau der Pumpe bei verspanntem Zustand des Rohrsystems. - Betrieb der Pumpe außerhalb des Einsatzbereichs, der im Pumpendatenblatt spezifiziert ist, z. B. zu hoher Systemdruck. - Öffnen und Instandhalten der Pumpe durch nicht qualifiziertes Personal.
  • Page 4: Allgemeine Hinweise

    Rotierende Teile Scher- und Quetschgefahr besteht aufgrund von offenliegenden rotierenden Teilen. - Alle Arbeiten nur bei Stillstand der Pumpe durchführen. - Vor Arbeiten die Pumpe gegen Wiedereinschalten sichern. - Unmittelbar nach Abschluss der Arbeiten alle Schutzeinrichtungen wieder anbringen bzw. in Funktion setzen.
  • Page 5: Montage

    Füllverluste weitgehend zu vermeiden, ist die Pumpe horizontal und möglichst auf Höhe oder unterhalb des Wasserspiegels zu montieren. Die AQUA Plus Timer OKU ist eine selbstansaugende Pumpe und sollte deshalb auf keinen Fall mehr als 2 m über dem Wasserspiegel montiert werden.
  • Page 6 5. Netzanschluss Elektroanschluss nur durch einen Fachmann! Vor Durchführung der Elektro- oder Wartungsarbeiten sind alle Teile spannungsfrei zu machen. Der Einsatz unserer Schwimmbadpumpen ist nur für Schwimmbecken und deren Schutzbereiche zulässig, die die DIN/VDE 0100 Teil 702 erfüllen. Die Pumpe darf nur über einen Fehlerstromschutzschalter von ≤...
  • Page 7: Technische Daten

    8. Reparaturen Alle Reparaturen dürfen nur durch den autorisierten Kundendienst durchgeführt werden. 9. Empfehlung Achtung Pumpen nur in gut vor Kindern gesicherten und abgeschlossenen W91.40.622-P Räumen aufbauen. Achten Sie auf die Eigenbelüftung des Motors. Der Aufstellungsort der Pumpe muss trocken und gut belüftet sein. Bitte keinerlei Fremdkörper in unmittelbarer Nähe der Pumpe aufstellen.
  • Page 8: Technische Änderungen Vorbehalten

    10. Technische Daten max. L ~120 Bundbuchse d=50 Aqua Plus Timer OKU Cillit Timer 80 110 140 Schlauchtülle für 1 / " bzw. 1 / " Schlauch max. L 506 511 511 max. L W91.40.625-1-P H [m] Aqua Plus 11 Timer OKU...
  • Page 9: Bedienung

    11. AQUA Plus Timer OKU Bedienoberfläche (1) Display: Zeigt die aktuelle Uhrzeit und den Zustand der Pumpe an, schaltet sich im Programm- modus nach 2 Minuten ohne Aktion ab. (2) LED: Zeigt den Zustand der Pumpe auch nach abgeschalteten Display an, blinkt, wenn die...
  • Page 10: Einstellen Der Uhrzeit

    Einstellen der Uhrzeit Einstellungsmenü Punkt "CLOC" auswählen und mit "SET/►" bestätigen, um die aktuelle Uhrzeit einzustellen. Zuerst wird die Stunde mit den Tasten "▲▼" eingestellt und mit "SET/►" gespeichert. Anschließend die Minu- WG27.50.087-P ten nach dem gleichen Prinzip. Einstellen der Programme WG27.50.088-P Die "SET/►"-Taste drücken, um in das Einstellungsmenü...
  • Page 12: Safety Symbols

    1. General AQUA TechniX GmbH, Neunkirchen am Sand 2. Safety Possible user errors - Installation of the pump with the pipes under tension. - Operation of the pump outside the area of application as specified on the datasheet for e.g. excessive system pressure.
  • Page 13: Rotating Parts

    Rotating parts Risk of crushing or shearing from exposed rotating parts. - Do not perform any work on the pump unless the power is shut down. - Before starting work, make sure the pump cannot inadvertently be switched on again. - Directly after finishing work, refit/reactivate all protective devices Electricity When working on the electrical unit, there is an increased risk of electrocution due to the damp...
  • Page 14 The AQUA Plus Timer OKU is self-priming and should never be installed more than 2 m above water level. Make sure that the suction line is not leaky, otherwise the pumps will prime insufficiently or not at all.
  • Page 15: Electrical Connection

    5. Electrical connection All electrical connections should be performed by a qualified expert only! Make sure all parts are free of tension before doing any maintenance work or electrical work. The use of pumps for swimming pools and the restricted area around them is only permitted if pumps are installed in accordance with DIN/VDE 0100 part 702.
  • Page 16: Technical Data

    8. Repairs Repairs are only to be done by an authorized service center. 9. Recommendations Caution Only install the pump in a lockable room, out of the reach of children. W91.40.622-P Ensure the motor’s cooling. The installation site must be dry and well ventilated.
  • Page 17 10. Technical data max. L ~120 Glue socket d=50 Aqua Plus Timer OKU Cillit Timer 80 110 140 Hose adapter 1 / ¼" or 1 / ½" hose max. L max. L 506 511 511 W91.40.625-2-P H [m] Aqua Plus 11 Timer OKU...
  • Page 18: User Interface

    11. AQUA Plus Timer OKU User interface (1) Display: Displays the current time and the status of the pump, turns its programme mode off after 2 minutes of inactivity. (2) LED: Displays the status of the pump even when the display has been turned off, flashes when the power supply is established and is continually lit when the pump is turned on.
  • Page 19: Setting The Time

    Setting the time Select "CLOC" in the settings menu and use the "SET/►" button to con- firm the current time. First of all the hour is set with the "▲▼" buttons and saved with the "SET/►" button. The minutes are set using the same principle.
  • Page 20 | 18...
  • Page 21: Risques Résiduels Chute De Pièces

    1. Généralités AQUA TechniX GmbH, Neunkirchen am Sand 2. Sécurité Erreurs d‘application possibles - Montage de la pompe avec système de canalisation déformé. - Utilisation de la pompe hors du domaine d‘utilisation spécifié dans la fiche technique de la pompe (par ex. pression système trop élevée).
  • Page 22: Informations Générales

    Pièces en rotation Risque de coincement et de cisaillement dû aux pièces en rotation apparentes. - Effectuer l‘ensemble des travaux uniquement à l‘arrêt de la pompe. - Avant de démarrer les travaux, sécuriser la pompe contre le ré-enclenchement. - Dès la fin des travaux, ré-enclencher tous les dispositifs de protection ou les remettre en service. Energie électrique L‘environnement humide entraîne un risque élevé...
  • Page 23 à l‘horizontale et si possible au niveau de l‘eau ou légèrement en dessous. La pompe AQUA Plus Timer OKU est auto-amorçante et ne devra pas être installée plus de 2 m au-dessus du niveau d‘eau. Veiller à...
  • Page 24: Raccordement Au Réseau Électrique

    5. Raccordement au réseau électrique Le branchement électrique doit être effectué obligatoirement par un spécialiste! Mettre hors tension toutes les unités avant l‘exécution de travaux électriques et de maintenance. L‘installation de nos pompes pour piscines est soumise au strict respect des prescriptions de la norme DIN/VDE 0100 partie 702.
  • Page 25: Réparations

    8. Réparations L‘ensemble des réparations doivent être exclusivement effectuées par un service après vente recommandé. 9. Recommandations Achtung Effectuer l‘installation des pompes dans des locaux sécurisés et fer- W91.40.622-P més à clef, ne permettant pas l‘acces aux enfants. Veiller à la bonne aération de la pompe par le ventilateur (pour que l‘air puisse circuler librement, il n‘est pas recommandé...
  • Page 26 10. Données techniques max. L ~120 Douille à collet d=50 Aqua Plus Timer OKU Cillit Timer 80 110 140 Embout cannelé pour tuyau 1 / " ou 1 / " max. L 506 511 511 max. L W91.40.625-3-P H [m]...
  • Page 27: Interface De Commande

    11. AQUA Plus Timer OKU Interface de commande (1) Ecran: Montre l‘heure actuelle et l‘état de la pompe, quitte le mode de programmation après 2 minutes sans action. (2) LED: Affiche l‘état de la pompe même après que l‘écran a été désactivé, clignote lorsque l‘alimentation en tension est rétablie et...
  • Page 28: Réglage De L'heure

    Réglage de l‘heure Dans le menu de réglage, sélecti- onner le point „CLOC“ et confirmer avec „SET/►“, pour régler l‘heure actuelle. On règle d‘abord l‘heure avec les touches „▲▼“ et on enregistre avec „SET/►“. Ensuite les minutes selon WG27.50.087-P le même principe. Réglage des programmes WG27.50.088-P Appuyer sur la touche „SET/►“...
  • Page 29 27 |...
  • Page 30: Eg-Konformitätserklärung

    EG - Konformitätserklärung DE / FR / EN / IT / NL / FI / ES / PL / CS / SK / DA / SE / TR / RU Déclaration CE de conformité / EC declaration of conformity / Dichiarazione CE di conformità / EG-verklaring van overeenstemming / EU-yhtäpitävyysilmoitus / Declaración de conformidad / Deklaracja zgodności CE / ES prohlášení...