locate flange gasket over bolts of oil furnace mounting flange, prior to placing
bottom front cover up to mounting flange.
○
Align mounting bolts on flange align with clearance holes in bottom front panel
when panel loosely fit in final position.
○
Correct position of bottom front panel has top flange of panel over top of firebox
front flange and underneath furnace bottom.
○
new bottom front panels in oil furnace module kits.
RIgHT HAND RA pANEL
NOTE
not all oil burner module kits require adapter collar and second fibre gasket.
Check "manual" Addendum accompanying oil furnace module for specific assembly details.
STEp #14
○
fasten bottom front cover to corner posts using hex head wildrill screws. Assemble burner, flange adapt-
er, and gaskets to oil furnace mounting flange bolts as per diagram.
○
Attach oil furnace sight glass, gasket, and bracket to bottom front panel using (2) hex screws.
brASS nuTS
oil burner
mounTinG
flAnGe
oil burner
ALL 115v ELECTRICAL pRE ASSEMBLED HARNESSES MUST BE INSTALLED AS pER
NO 115v ELECTRIC CIRCUIT HARNESS OR FIELD WIRINg MAY pASS THROUgH CLEARANCE
SpACE BETWEEN HMF150/200 FURNACE BOTTOM AND FLOOR.
FAILURE TO COMpLY MAY RESULT IN ELECTRIC SHOCk, FIRE, pROpERTY DAMAgE OR
LEFT HAND RA pANEL
AdAPTer
CollAr
fibre
GASkeTS
INSTRUCTIONS.
pERSONAL INjURY.
FIREBOx
FRONT
FURNACE BOTTOM
COMBUSTION CHAMBER
SECTION A-A
SCALE 1 : 16
boTTom fronT
oil furnACe
GASkeT
SiGHT GlASS
SiGHT GlASS brACkeT
LEFT HAND RA CONFIg SHOWN
W415-1013 / A / 06.05.12
27
FLANGE GASKET
OIL FURNACE
FLUE
OIL FURNACE
Cover
flAnGe