STEp #12A - For installation in HMF200 only.
The 5" flue pipe of the
tions for mounting the flue extension are provided on leaflet supplied with the kit. once extension has
been firmly secured, continue with Step #12b.
STEp #12B
insert the stainless steel oil furnace combustion chamber/heat exchanger (Hmfk-CmbCH-1), into the
lower cavity of Hmf150/200 body (see diagrams). ensure the heat exchanger is on the same side as the
blower.
AIR FLOW
DIRECTION FROM
BLOWER MODULE
HEAT EXCHANGER
LEFT HAND RA CONFIgURATION
TAkE pARTICULAR CARE TO ORIENTATE OIL FURNACE AS pER DIAgRAMS FOR LEFT AND RIgHT
HAND RA. THE OIL FURNACE COMBUSTION CHAMBER AND HEAT ExCHANgER WAS DESIgNED
AND TESTED FOR THE ExCHANgER SECTION OF THE ASSEMBLY TO FACE THE AIR STREAM
COMINg FROM THE BLOWER MODULE. INCORRECTLY ASSEMBLED OIL FURNACE COMpONENTS
CAN RESULT IN pOOR pERFORMANCE AS WELL AS COMpONENT AND/OR pROpERTY DAMAgE.
Push the oil combustion chamber/heat exchanger into the cavity until the flue pipe protrudes through the
opening of the rear furnace panel.
STEp #13
Align mounting flange and bolts with flange pattern on new bottom front panel (supplied) with Hmfk-
ofrf40, Hmfk-ofbnx module kits in both left and right hand rA versions.
W415-1013 / A / 06.05.12
Hmfk-CmbCH-1
must be extended using kit number Hmfk-fe. detailed instruc-
COMBUSTION CHAMBER
COMBUSTION CHAMBER
HEAT EXCHANGER
RIgHT HAND RA CONFIgURATION
AIR FLOW
DIRECTION FROM
BLOWER MODULE