6.4.1 Fixing to parapet

First of all secure the base of the adapter to the final
destination. Use screws that can bear at least 4 times
the weight of the unit.
Apply a generous amount of thread locking
compound (Loctite 270).
Tighten the screws.
The thread compound must cure for one hour, allow
for this period prior to completing the installation.
It's possible to secure the base (01) to the column
adapter NXFWBT using 4 M5 countersunk screws (02)
provided.
Secure the joint (03) to the base through nuts and
washers supplied.
03
02
01
Fig. 7
Fasten the housing at the junction with the M6
screws and washers provided.
Fig. 8
Apply a generous amount of thread locking
compound (Loctite 270).
Tighten the screws.
Pay attention to the fixing. Tightening
torque: 9-12Nm max.
The thread compound must cure for one hour, allow
for this period prior to completing the installation.
MNVCMHX_1432_EN

6.4.2 Fixing with bracket

The bracket can be fixed to the vertical wall. Use
screws and wall fixing devices that can bear at least
four times the weight of the unit.
Fig. 9
To fix the device to the bracket, use 4 washers, 4
stainless steel grower washer, 4 socket head stainless
steel screw M6 provided.
Make sure the thread are free of dirt and debris.
Apply a generous amount of thread locking
compound (Loctite 270) on the 4 screws.
Tighten the screws.
Pay attention to the fixing. Tightening
torque: 9-12Nm max.
The thread compound must cure for one hour, allow
for this period prior to completing the installation.