Special Conditions For Safe Use; Additional Information - Videotec MAXIMUS MHX Manuel D'instructions

Masquer les pouces Voir aussi pour MAXIMUS MHX:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 97

3.1.4 Special conditions for safe use

• The O-ring at the back cover shall be replaced by a new one after each opening of the back cover, in order to
maintain the IP66/67 ingress protection rating.
• The maximum constructional gaps (ic) are less than that stated in Table 2 of EN 60079-1:2007. Conform clause
5.1 of EN 60079-1:2007, as reported in table.
FLAMEPATH
Spigot joint. Between rear cover and main
body housing component. Drawings
BRT2MHXNFP and CRP2MHXNC.
Cylindrical joint. Between wiper shaft
and bore. Drawings BRT2MHXALWIP and
BRT2MHXBUST.
Tab. 2
• The cameras to be installed shall not be electromagnetic or contain lasers, continuous wave sources or
ultrasonic energy radiating equipment.
• The cameras to be installed shall not contain cells or batteries.
• The cameras to be installed shall dimensionally be no greater than 80mm (wide) x 82mm (high) x 245mm
(long) and be of a basic geometric form, and installed at least 10mm from the inner surface of the enclosure
window.

3.1.5 Additional information

The MHX and MHXT series CCTV camera housings in addition have passed the tests for Ingress Protection to
IP66 and IP67 in accordance with EN60529:1991/A1 2001.
10
DIMENSIONS
Shaft: 132.96mm min
Bore: 133.06mm max
Shaft: 12.79mm min
Bore: 13.03mm max
MAXIMUM GAP
MINIMUM WIDTH
0.1mm
59.4+4.22mm
0.24mm
40.1mm
MNVCMHX_1432_EN