Sun Oracle SPARC M5-32 Guide D'administration page 177

Masquer les pouces Voir aussi pour SPARC M5-32:
Table des Matières

Publicité

->
load -source http://
NOTE: An upgrade takes several minutes to complete. ILOM
     will enter a special mode to load new firmware. No
      other tasks can be performed in ILOM until the
     firmware upgrade is complete and ILOM is reset.
 
NOTE: HOST0 is powered on; HOST0 firmware will be updated
      automatically when HOST0 is restarted.
 
Are you sure you want to load the specified file (y/n)?
Preserve the configuration (y/n)?
2012-10-05 07:06:53 Download firmware package ...
2012-10-05 07:09:54 Check firmware package ...
Incompatible FW version running on domain. Stop domain ID 0 before
upgrading firmware upgrade failed: FW compatibility check failed
2012-10-05 07:09:56 Firmware upgrade cancelled
 
Firmware update failed.
load: Command Failed
->
Remarque
Comme indiqué dans cet exemple, vous devez mettre hors tension le domaine physique spécifié
(PDomain_0 dans cet exemple) pour que la commande load soit correctement exécutée.
• Si vous sélectionnez l'option no-preserve-configuration de la commande load en répondant
no à la question "Preserve the configuration (y/n)", il faut mettre tous les hôtes hors tension. Si
vous exécutez la commande load alors que des hôtes sont sous tension et que vous répondez
"no" à la même question, les messages suivants s'affichent dans la sortie de l'opération de
chargement :
->
load -source http://
NOTE: An upgrade takes several minutes to complete. ILOM
     will enter a special mode to load new firmware. No
     other tasks can be performed in ILOM until the
     firmware upgrade is complete and ILOM is reset.
 
NOTE: HOST0 is powered on; HOST0 firmware will be updated
     automatically when HOST0 is restarted.
 
Are you sure you want to load the specified file (y/n)?
Preserve existing configuration (y/n)?
2013-01-28 20:35:51 Download firmware package ...
2013-01-28 20:38:46 Check firmware package ...
No-preserve-configuration option passed. Stop domain ID 0
before upgrading firmware
upgrade failed: No-preserve-configuration option passed,
stop all domains before upgrading firmware
2013-01-28 20:39:16 Firmware upgrade cancelled
 
Firmware update failed.
Chapitre 9. Mise à jour du microprogramme
xxx.xxx.xx.xxx/pathname
y
xxx.xxx.xx.xxx/pathname
n
y
y
177