• Si certains hôtes sont sous tension, (HOST0 dans cet exemple), mais qu'aucune incompatibilité
Remarque
Comme indiqué dans cet exemple, les microprogrammes de PDomain_0 ne sont automatiquement mis
à jour que lors du redémarrage du domaine physique.
• Si une opération de chargement détectant un microprogramme incompatible se produit,
176
Serveurs SPARC M5-32 et SPARC M6-32 · Guide d'administration · Décembre 2014
->
load -source http://
NOTE: An upgrade takes several minutes to complete. ILOM
will enter a special mode to load new firmware. No
other tasks can be performed in ILOM until the
firmware upgrade is complete and ILOM is reset.
Are you sure you want to load the specified file (y/n)?
Preserve the configuration (y/n)?
2012-10-05 07:59:29 Download firmware package ...
2012-10-05 08:02:32 Check firmware package ...
2012-10-05 08:02:58 SP /SYS/SPP0 firmware update started ...
2012-10-05 08:02:58 SP /SYS/SPP1 firmware update started ...
.................................................................
Firmware update is complete.
ILOM will now be restarted with the new firmware.
->
n'est détectée, la mise à niveau se déroule comme suit :
->
load -source http://
NOTE: An upgrade takes several minutes to complete. ILOM
will enter a special mode to load new firmware. No
other tasks can be performed in ILOM until the
firmware upgrade is complete and ILOM is reset.
NOTE: HOST0 is powered on; HOST0 firmware will be updated
automatically when HOST0 is restarted.
Are you sure you want to load the specified file (y/n)?
Preserve the configuration (y/n)?
2012-10-05 06:43:13 Download firmware package ...
2012-10-05 06:46:29 Check firmware package ...
2012-10-05 06:47:09 SP /SYS/SPP0 firmware update started ...
2012-10-05 06:47:10 SP /SYS/SPP1 firmware update started ...
.................................................................
Firmware update is complete.
ILOM will now be restarted with the new firmware.
->
l'opération se déroule comme suit :
xxx.xxx.xx.xxx/pathname
y
xxx.xxx.xx.xxx/pathname
y
y
y