5.0 FRAMING
EN
IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING
IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE
APPLIANCE ENCLOSURE BE "FINISHED" (I.E.: DRYWALL / SHEETROCK), AS YOU WOULD FINISH
ANY OTHER OUTSIDE WALL OF A HOME. THIS WILL ENSURE THAT CLEARANCE TO
DO NOT BUILD SHELVES OR CUPBOARDS INTO THE AREA ABOVE THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48" (121.9cm)
NOTE : USE METAL STUDS WHEREVER NON-COMBUSTIBLE FACING IS REQUIRED.
* Allow for finished floor and hearth thickness when setting these dimensions.
** When constructing the enclosure allow for finishing material thickness and to maintain clearances.
W415-1676 / A / 03.17.17
COMBUSTIBLES IS MAINTAINED WITHIN THE CAVITY.
AWAY FROM THE FRONT FACE OF THE APPLIANCE.
96"
(243.8cm)
MIN.
81 1/4"
(206.4cm) *
60"
(152.4cm)
METAL STUD
29 5/8"
(75.2cm)**