POTENZE IMPEGNATE PER I VENTILATORI TRIFASE MONTATI SUI CONDENSATORI SDHV 900 O RAFFREDDATORI DI LIQUIDO SDHL 900
POWER DRAWN BY THREE PHASE VENTILATOR MOTORS INSTALLED ON SDHV 900 CONDENSERS OR SDHL 900 DRY COOLERS
PUISSANCES UTILISEES PAR LES VENTILATEURS TRIPHASES MONTES SUR LES CONDESEURS SDHV 900 OU LES AEROREFRIGERANTS SDHL 900
STROMAUFNAHME FÜR DIE IN DEM VERFLÜSSIGERN SDHV 900 BZW. FLÜSSIGKEITS RÜCKKÜHLERN SDHL 900 EINGEBAUTEN DREHSTROMVENTILATOREN
Ventilatori / Fans / Ventilateurs / Ventilatoren
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
6,3
1x2
1
2
12,6
1x3
1
3
18,9
1x4
1
4
25,2
1x5
1
5
31,5
1x6
1
6
37,8
1x7
1
7
44,1
2x2
2
2
25,2
2x3
2
3
37,8
2x4
2
4
50,4
2x5
2
5
63
2x6
2
6
75,6
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
3,5
1x2
1
2
7
1x3
1
3
10,5
1x4
1
4
14
1x5
1
5
17,5
1x6
1
6
21
1x7
1
7
24,5
Mod. ventilatori / Fans type / Mod. ventilateurs
Mod. Ventilatoren / Mod. ventiladores
(A)
1x1
1
1
0,8
1x2
1
2
1,6
1x3
1
3
2,4
1x4
1
4
3,2
1x5
1
5
4
1x6
1
6
4,8
1x7
1
7
5,6
Ø 900 mm
FC 900
QE...
FU1 FU2 FU3
FU1*
1/20A
1
-
-
8
2/20A
2
-
-
16
3/20A
3
-
-
25
4/32A
2
2
-
16
5/32A
3
2
-
25
6/60A
2
2
2
16
7/60A
3
2
2
25
4/32A
2
2
-
16
6/60A
2
2
2
16
8/60A
3
3
2
25
2x 5/32A
2x3 2x2
-
2x25
2x 6/60A
2x2 2x2 2x2
2x16
FE 900
QE...
FU1 FU2 FU3
FU1*
1/20A
1
-
-
6
2/20A
2
-
-
10
3/20A
3
-
-
16
4/20A
4
-
-
20
5/20A
5
-
-
25
6/32A
3
3
-
16
7/32A
4
3
-
20
FE 900
QE...
FU1 FU2 FU3
FU1*
1/20A
1
-
-
2
2/20A
2
-
-
4
3/20A
3
-
-
4
4/20A
4
-
-
4
5/20A
5
-
-
6
6/20A
6
-
-
6
7/20A
7
-
-
8
(A)
6P
FU2
FU3
R2PR-R2TE-RS
-
-
12A
-
-
20A
-
-
20A
16
-
25A
16
-
40A
16
16
40A
16
16
60A
16
-
25A
16
16
40A
25
20
60A
2x16
-
2x 40A
2x16
2x16
2x 40A
6P
FU2
FU3
R2PR-R2TE-RS
-
-
12A
-
-
12A
-
-
12A
-
-
20A
-
-
20A
16
-
25A
16
-
25A
12P
FU2
FU3
R2PR-R2TE-RS
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
-
-
12A
9
REGOLATORE / SPEED REGULATOR
REGULATEUR / REGLER
R2PR - R2TE - RS
Quando è indicata la quantità dei
ventilatori con 2xn ventilatori, su
ogni contattore sono collegati 2
ventilatori in parallelo.
When the fan number is indicated
as 2xn fans, two parallel fans are
wired on each contactor.
Lorsqu'il est indiqué un nombre de
ventilateurs 2xn, chaque
contacteur contrôle deux
ventilateurs en parallèle.
Wenn bei der Ventilatoranzahl 2xn
Ventilatoren angegeben sind, sind
swei Ventilatoren parallel auf elnen
Schütz verdrahtet.
Tk
~
Ma
Tk
Mb
~
Alla rete / To mains
Auréseau / Zum Netz